709180
12
Zoom out
Zoom in
Vorherige Seite
1/28
Nächste Seite
Unit Switch To save the battery on account of the increased The room in which the battery is located must be
The power converter can be switched on via the power dissipation on standby (approx. 1.8 W). well ventilated in accordance with the regulations.
unit switch to the left of the shockproof electric Do not mount the unit directly over heat sources
socket. If no AC consumers are being run off the Installation nor on easily ignitable materials. There must be a
unit, then the power converter is best switched off The SHS200 solar station must be installed near clear space of >100 mm above and below the unit.
the battery in accordance with its protection class.
Connection Schematic circuit diagram
The wiring and fuse protection of the system must conductor on the output side is not keep voltage drops on the line as low as
be carried out in accordance with the regulations permitted and will destroy the unit! possible. If the consumer connections are
on line protection or in accordance with the 2. Connect the battery to the designated screw incorrectly poled, these can still be destroyed
regulations applicable at the time. Before starting terminals -B +B, taking care to pole correctly to despite the fuse protection.
any wiring work, check for correct polarity and that avoid short circuits. In order to keep the voltage
the voltage of the individual system components, drop low and also the heating of the cable
i.e. of the solar station, solar modules, lead-acid connected with it, a flexible cable cross-section
battery, consumers, complies with that specified. If of 4.0 mm² is recommended. A corresponding
in doubt, consult your specialist dealer! When fuse should always be sited directly at the
installing the unit, it is important to observe the battery's plus pole in accordance with the
sequence described: regulations on line protection. The cables
connecting the battery to the station should not
1. Check to see whether the connected battery exceed a length of 3 m. The green LED on the
already has an earth connection. In this case, unit should light up. If not, check the fuse links
the minus pole must be earthed because the and make sure that voltage is being applied to
solar station is earthed internally. If not, connect the connection lead.
the unit's earth connection to your home's earth 3. If the station is so far working correctly, connect
connection. If you do not have an earth the solar module to the screw terminals -M +M,
connection, an earth connection must be taking care to pole correctly.
created in accordance with the regulations (e.g. 4. Connect the DC consumer to the screw
a ground rod). Under no circumstances is it terminals -L +L, taking care to pole correctly.
permitted to operate the unit unearthed Use cable of at least 1.5 mm² or in accordance
because operation of class 1 equipment in with the line protection. If the consumers are a
the presence of an error/failure can prove distance away from the solar station, you should
life-threatening. Earthing the neutral select a larger cable cross-section in order to
Wiring
- Caution: Take care to pole correctly! Follow the safety instructions!
GB
Retain these installation, operating and maintenance instructions for the full duration of the operator’s service life!
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Novoferm APS 230 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Novoferm APS 230

Novoferm APS 230 Zusatzinformation - Alle Sprachen - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info