709128
18
Zoom out
Zoom in
Vorherige Seite
1/43
Nächste Seite
displayed.
Press the second button at the transmitter with which
the 4-min light is to be switched on. As soon as the
code has been read in, the red point display (a) will
flash 5 times to acknowledge the entry. Figure 0 will
be displayed. Menu finished.
Deleating all the hand transmitters programmed
for the operator:
Menu stage 3: Setting / adjusting the top end-
of-travel position
Menu stage 4: Setting / adjusting the bottom
end-of-travel position
Force-learningcycle
Plug in the operators main plug while pressing
button .
Keep button pressed for 3 seconds. Number 3
appears in the display 8 a.
Wait a short while until the 3 starts flashing.
Press button and make sure that the door travels in
the OPEN direction.
If the door closes in the wrong direction, after
having pressed , keep button pressed for
another 3 seconds. 3 flashes briefly. The
travelling direction is altered.
Now travel by pressing button into the desired door
end position OPEN 17b.
By pressing button , the position can be corrected
into direction CLOSE.
Once the desired OPEN end-of-travel position has
been reached, press button . The operator stores
the OPEN end-of-travel position and 4 appears in
the display.
Wait a short while until 4 starts flashing.
ress button . The operator causes the door to
travel in the CLOSE direction as long as the button is
pressed. The position can be altered to the OPEN
direction via button ..
Once the desired CLOSE end-of-travel position has
been reached, press button . The operator stores
the CLOSE end-of-travel position and 0 appears in
the display.
We recommend setting the suitable door type in
menu stage 8 prior to the force-learning cycle.
During this opening and closing cycle, the
operator learns the force required to open and close
the door. The cycles
must not be interrupted. During these cycles must
not be interrupted. During these cycles 0 appears
in the display.
- Press button . The operator causes the door to
open until the top end-of-travel position has been
reached.
- Now press button again. The operator causes
the door to close until the bottom end-of-travel
position has been reached.
- After approx. 2 seconds, 0disappears.
P
Checkingtheforcelimitdevice
!
!
- Position the force-measuring device
(dynamometer) in the closing area.
(If a measuring device is not available, use, for
example, the operators cardboard box)
- Start the door from the OPEN end-of-travel
position.
- The door travels towards the obstruction, stops
and re-opens.
If the door springs were altered, the force-learning
operation must then be repeated:
Call up menu stage 5 and keep button depressed
for 3 seconds. A "0" is displayed. Then carry out
A force limit does not apply!
17
18
19
20
force-learning operations as explained under point
.19
Special settings
Menu stage 5: The opening force limit
Menu stage 6: The closing force limit
Menu stage 7: Light phases
Menu stage 8: Door fitting
Menu stage 9: special functions
If you have previously quit the setting menu, press
button for 3 seconds until 3 appears. Then press
button twice until 5 appears.
After approx. 2 seconds, the display flashes showing
the set value of the opening force limit. The force limit
setting can be increased for decreased via buttons
and .After setting the value, press button .
The display shows 6.
After approx. 2 seconds, the display starts flashing,
and the set value for the closing force limit is
displayed.
The force limit setting can be increased or decreased
via buttons and .
After setting the value, press button . 0 appears
in the display.
Finally, check the force settings, and, if necessary,
repeat the setting procedure.
The maximum force at the main closing edge must
not exceed 150 N!
Keep button pressed for 3 seconds. A "3" is
displayed. Press button repeatedly until menu 6
is displayed. Keep button pressed again for 3
seconds until a "7" is displayed.
Menu Light Warning 24V
value phase phase
0 60 s - 60 s
1 120 s - 120 s
2 240 s - 240 s
3 0 s - 0 s
4 0 s 3 s 0 s
5 60 s 3 s 0 s
6 120 s 3 s 0 s
7 60 s 0 s TAM
8 120 s 0 s TAM
9 240 s 0 s TAM
The factory setting is 1.
TAM: OPEN signal, when the door is not closed 24V
are available for signalling.
Press button . 8 appears in the display.
Menu Start Stop Start Stop
value open open closed closed
1 15 0 15 0
4 25 30 25 40
5 15 15 15 55
6 15 15 15 15
7 35 35 65 45
8 55 15 15 100
9 only soft run
These values correspond to the soft runs
measured in cm at the carriage.
In order to access the menus for the special settings,
keep key pressed for 3 sec until figure 3 is
displayed. Press key to by-pass menu step 3.
Now keep key pressed for 3 sec until figure 5 is
displayed. Press key to by-pass menu steps.
When the advance warning time is set, the light and
24 V will be switched on before the drive starts
running.
0 0 0 0 0
2 0 15 0 40
3 15 15 15 35
Push button .9is displayed.
Menu Operating mode
value
The 2nd push button of the transmitter has
to be teached-in again after changing the operation
mode.
. Loosen bolts on motor head with wrenches (SW
10 and 17mm) and screw them back on the
other side .
If the control unit cannot be positioned directly
underneath the track , the coiled cable can then
be routed to the motor head using the supplied
second cable clamp and the punched tape . The
extendible part of the coiled cable may be stretched
by a maximum of factor 3 and the permanently laid
part by a maximum of factor 7.
If the coiled cable is not long enough, the extension
set (accessory) should be used.
The option of connecting the wicket door contact
to drive unit is an advantage.
- Remove housing .
- On the white plastic component, break out the
side wall towards the door .
- Route cable from wicket door contact over the
lifting arm and fasten with cable binder .
- Remove jumper from terminal block and
insert cable .
- Place housing back on again and screw down
.
: Open wicket door, "8" is displayed.
0
1
The ventilation position can be initiated by
pressing the second push button on the
hand transmitter or via the signal 112
internal push button (accessory).
2
Partial opening of approx. 1m can be
initiated by pressing the second push
button on the hand transmitter or via the
signal 112 internal push button
(accessory).
The cover on the control unit is used as an impulse
generator for opening and closing from inside the
garage. Briefly press the cover and the operator
starts up .
The operator is equipped with a quick release. By
pulling the pull cord with knob , the operator can
be permanently disengaged from the door . 8 is
displayed.
The motor head can be re-engaged at any point
between the two limit switch actuators. To lock in
place, press down lever .
If favoured by the structural conditions on site, the
operator can also be installed on the left-hand side
ck on the other side .
Normaloperation
Normaloperationwithventilation
position
Partialopeningofsidesectionaldoors
Internalimpulsegenerators
Disengagement
22a
22b
22c
InstallationonLHsideofdoor
23c
Advice:
23a
23b
23c
Low-mountedcontrolunit
24a
24b
Connectionforwicketdoorcontact
25a
25b
25c
25d
25e
25f
Check
21
22
23
24
25
Retain these installation, operating and maintenance instructions for the full duration of the operators service life!
GB
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

novoferm-novoport-iii-generation

Suche zurücksetzen

  • Tot blöckiert auf halberStrecke. Was ist die Ursache?

    Eingereicht am 11-7-2024 18:32

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Novoferm NovoPort III Generation wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info