709128
19
Zoom out
Zoom in
Vorherige Seite
1/43
Nächste Seite
Operating Instructions
Information regarding the operating instructions
Allpersonsusingthedoorsystemmust
beshownhowtooperateitproperlyand
safely.
- Whentheoperatorisbeingactuated,any
openingandclosingphasesmustbe
monitored.
- Keephandtransmittersoutofthereachof
children.
- Itmustbeensuredthatneitherpersonsnor
objectsarelocatedwithinthedoor'srangeof
travel.
Functionalsequence
23
Internalsafetydevice
Externalsafetydevices
Quickrelease
22a
22c
These operating instructions describe how to use the
product properly and safely. The safety advice and
instructions as well as the local health and safety
regulations and general safety regulations for the
range of use must be observed.
The garage door operator can be actuated by push-
button on the control unit (figure ) or by other
impulse generators, such as hand transmitters, key
switches etc. It is only necessary to generate a short,
sharp impulse.
- Initial impulse:
Operator starts up and causes the door to travel
to the set OPEN or CLOSE end-of-travel
positions.
- Impulse generated whilst the door is in motion:
Door stops
- A new impulse:
Door continues to move but in the opposite
direction.
If the closing door encounters an obstruction, the
operator stops and causes the door to open to its top
end-of-travel position in order to clear the
obstruction.
During the last 2 seconds of closing, the door only
opens slightly, this being sufficient to clear the
obstruction but otherwise preventing anyone from
being able to see inside the garage.
If the opening door encounters an obstruction, the
operator stops immediately. The door can be closed
again by generating a new impulse.
- Wicket door contact STOP A
An open wicket door stops the operator
immediately or prevents it from starting up.
- Photocell defective (STOP B)
If the photocell is interrupted whilst the door is
closing, the door stops and reverses direction.
An interruption whilst the door is opening has no
effect.
When altering settings or making adjustments, in the
event of a power failure or malfunctions, the door can
be disengaged from the operator by actuating the
pull cord with knob on the lifting arm (figure ), so
that it can be operated manually.
To resume operation of the operator, press the lever
on the motor head (figure ) and the operator re-
engages.
If the door is to be operated manually over a longer
period of time, then the door latches which were
taken out of service for power operation, must be
refitted, otherwise the door will not be latched when
closed.
Lighting
16
Changingthelightbulb
Signal light
Handtransmitters
15 16
Empty batteries must be disposed of separately
(toxic waste)!
The lighting switches on automatically whenever a
start impulse is generated and switches off again
after the set time phase (factory setting approx. 90
seconds).
A second button on the hand transmitter can be
programmed for 4-minutes light (figure ). When
the button on the hand transmitter is pressed, the
light switches on independent of the motor and
switches off again after approx. 4 minutes.
Pull out the mains plug and open the lamp shade
using a Phillips screwdriver size 2 x 100. Replace the
light shade (230 V, 40 W, cap E27) and screw the
lamp cover back on again.
If a signal light for signalling the opening and closing
phases is installed, this flashes together with the
lamp in the operator as soon as a start impulse is
generated. The operator starts with a time delay in
accordance with the set early warning phase (see
Special Settings in menu stage 7).
- Programming further hand transmitters:
See menu stages 1 and 2 (figures and ).
- Changing the battery: slide back the battery
compartment cover on the hand transmitter.
Take out the battery.
- Insert a new battery. Be sure to pole correctly!
Slide the cover back on.
Further operating modes
In menu 9, another operating mode can be chosen.
For the setting applying to menu 9, see parantheses.
Normal operation for ventilation position (1)
Operation on a side-opening sectional door (2)
The ventilation position is designed to allow
ventilation of the garage. For this, the door is opened
approx. 10 cm.
Actuation as for normal operation.
By pressing the 2 button on the hand transmitter or
generating an impulse via another device, the door
can be brought into the ventilation position from any
given position.
The gate will close automatically after 60 min or can
be closed earlier by any impulse transmitter.
Instead of opening the door fully, the door can be
partially opened by approx. 1 m in order to provide
access to the garage.
By pressing the 2 button on the hand transmitter or
generating an impulse via another device, the door
can be brought into the partially open state from any
given position.
nd
nd
Maintenance/Checks
The operator control unit features a dual-processor
safety system to monitor the force limit.
The integral force cut-out is automatically tested at
each end-of-travel position.
The door system must be checked before initial
operation and at least once a year thereafter, In the
process, the force limiting device (figure ) must be
tested!
CAUTION! If the closing force is set too
high, this can result in injury to persons and
damage to property.
The opening force can be re-adjusted in menu stage
5, the closing force in menu stage 6.
Foryourownsafetywerecommend
that thedoorsystembecheckedbya
specialistafterinitialinstallationand
thenregularlyatintervalsof1year
minimum.
Monitoringtheforcelimit
20
Retain these installation, operating and maintenance instructions for the full duration of the operators service life!
GB
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

novoferm-novoport-iii-generation

Suche zurücksetzen

  • Tot blöckiert auf halberStrecke. Was ist die Ursache?

    Eingereicht am 11-7-2024 18:32

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Novoferm NovoPort III Generation wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info