OC1 OPERATING MANUAL
© 2002 Design, 2009 Doc. No. 12-2761-r04 (9/6/11)
Fly/Dsat, information includes (Fig. 30A/B):
> Time to Fly (hr:min), 0:00 if no dive yet, with graphic FLY
> Time to Desat (hr:min), 0:00 if no dive yet, with graphic DSAT
> Time (clock) icon
• S < 2 sec, revert to Menu
• L (on closure) to activate Backlight
NORM PLAN MODE
No Deco Dive Times (NDLs) in NORM Plan Mode are based on the Algorithm selected (DSAT or PZ+) and only on the FO2 set
for Gas 1. FO2 set for Gas 2 and 3 are not used.
NORM Menu >> Plan Lead-in >> PDPS
Plan Lead-in, information includes (Fig. 31A/B):
> Graphic PLAN
> Graphic FO2_1 (Gas 1)
> Graphic Air or numeric % value (21 to 50), indicating the FO2 set for Gas 1
> Graphic PO2 with PO2 Alarm value set (1.20 to 1.60), if Nitrox, blank if Air
> Nx icon, if Nitrox
• S < 2 sec to access PDPS
• L (on closure) to activate Backlight
PDPS (Pre Dive Planning Sequence)
The PDPS displays Depths and allowable No Deco Dive Times. It will sequence through Depths from 30 to 190 FT (9 to 57 M),
or the Max Depth that will allow theoretical No Deco Dive Time of at least 1 minute based upon the previous dive profiles in a
series of repetitive dives and taking into account descent and ascent rates of 60 FPM (18 MPM).
When the Conservative Factor is set On, No Deco Dive times are reduced to the values of the next 3000 foot (915 meter) higher
Altitude. Refer to tables in back.
PDPS, information includes (Fig. 32A/B):
> Max Depth with MAX and FT (or M) icons, if Nitrox, blank if set for Air
> Plan Depth value with graphic FT (or M)
> Graphic NDC (or OTR) with Dive Time allowed (hr:min) with Time (clock) icon, no OTR if Air
> Graphic PO2 with PO2 Alarm value set (1.20 to 1.60), if Nitrox, blank if set for Air
> Nx icon, if Nitrox
• A (hold) to scroll upward through screens at a rate of 8 per second increasing planned Depth from 30 to 190 FT (9 to 57 M)
in increments of 10 FT (3 M)
• A (< 2 sec) to step upward through screens one at a time
• M (< 2 sec) to step back through screens one at a time
• S (< 2 sec) to revert to the Plan Lead-in screen
• L (on closure) to activate Backlight
NORM/GAUG LOG MODE
Information from the latest 24 NORM and/or GAUG dives is stored for viewing. After exceeding 24 dives, the most recent dive
is stored while the oldest is deleted.
> Dives are numbered from 1 to 24 starting each time NORM (or GAUG) Dive Mode is activated. After the post dive 24 hour
period has elapsed, the first dive of the next operation period is #1.
> During the first 10 minutes after a dive (Transition Period), that dive’s Log screens can be viewed. After 10 minutes, the Log
screens for all dives stored can be viewed.
> In the event that a dive’s elapsed time (EDT) exceeds 9:59 (hr:min), the data at the 9:59 interval is recorded in the Log upon
surfacing of the unit.
NORM Menu >> Log Preview >> Log Data 1 >> Log Data 2
Log Preview, information includes (Fig. 33):
> Log Mode (book) icon
> Graphic NO-D (or DECO or GAUG or VIOL)
> Graphic DIVE and dive number (1 to 24, 0 if no dive yet).
> Time dive began (hr:min) with Time (clock) icon and A (or P), and the graphic ALT if Alternate Time
> Date, the dive was conducted
> Nx icon, if Nitrox
• A (hold) to scroll upward through Preview screens at a rate of 8 per second
• A (< 2 sec) to step upward through screens one at a time
• M (< 2 sec) to step back through screens one at a time
• S (< 2 sec) to access the dive's Log Data 1 screen
• L (on closure) to activate Backlight
Fig. 30A - FLY/SAT
(10 min after dive)
Fig. 30B - FLY/SAT
(< 10 min after dive)
Fig. 31A - PLAN LEAD-IN
(Gas 1 set for Air)
Fig. 31B - PLAN LEAD-IN
(Gas 1 set for Nitrox)
Fig. 32A - PDPS
(nitrogen control)
Fig. 32B - PDPS
(oxygen control)
Fig. 33 - LOG PREVIEW
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oceanic OC1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Oceanic OC1

Oceanic OC1 Zusatzinformation - Deutsch - 2 seiten

Oceanic OC1 Kurzanleitung - Deutsch - 2 seiten

Oceanic OC1 Bedienungsanleitung - Deutsch - 68 seiten

Oceanic OC1 Bedienungsanleitung - Englisch - 180 seiten

Oceanic OC1 Zusatzinformation - Französisch - 2 seiten

Oceanic OC1 Kurzanleitung - Französisch - 2 seiten

Oceanic OC1 Bedienungsanleitung - Französisch - 68 seiten

Oceanic OC1 Zusatzinformation - Italienisch - 2 seiten

Oceanic OC1 Bedienungsanleitung - Italienisch - 68 seiten

Oceanic OC1 Bedienungsanleitung - Spanisch - 68 seiten

Oceanic OC1 Bedienungsanleitung - Türkisch - 180 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info