OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r02 (9/12/13)
FULL HISTORY DATA 2, information is to include (Fig. 128):
> Max Depth with FT (or M) and MAX icons.
> Graphics DEEPEST EVER,indicating that the information displayed is for the deepest Max Depth ever recorded and the
Elapsed Dive Time is associated with that Max Depth.
> Elapsed Dive Time (min:sec) for that dive with graphic EDT.
S (< 2 sec) - to access the Full History Data 3 screen.
S (2 sec) - to exit and revert to the Log/History Menu.
• M (2 sec), or 2 min of no button action, - to exit and revert to the Surface Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
• L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
FULL HISTORY DATA 3, information is to include (Fig. 129):
> Max Depth with FT (or M) and MAX icons.
> Graphics LONGEST EVER, indicating that the information displayed is for the longest Elapsed Dive Time ever recorded and
the Max Depth displayed is associated with that Dive Time.
> Elapsed Dive Time (min:sec) with graphic EDT.
S (< 2 sec) - to access the Full History Data 4 screen.
S (2 sec) - to exit and revert to the Log/History Menu.
• M (2 sec), or 2 min of no button action, - to exit and revert to the Surface Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
• L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
FULL HISTORY DATA 4, information is to include (Fig. 130):
> Max Depth with FT (or M) and MAX icons, the average of all Max Depths ever recorded.
> Graphics AVERAGE FOR ALL, indicating that the information displayed represents Averages.
> Elapsed Dive Time (min:sec) with graphic EDT, the average EDT of all dives ever recorded.
> The average number of dives conducted each day (up to 99) with the graphic divE.
S (< 2 sec) - to access the Full History Data 1 screen.
S (2 sec) - to exit and revert to the Log/History Menu.
• M (2 sec), or 2 min of no button action, - to exit and revert to the Surface Main.
• L (< 2 sec) - to toggle the Backlight On/Off.
Will be On for the duration time set.
• L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
----------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------
SET ALARMS MENU - FREE & TECH FREE MODES
FREE Menu selections >> Audible* >> SRT* >> RTI* >> RDI* >> DD1 >> DD2 >> DD3.
TECH FREE Menu selections >> Audible* >> SRT* >> RTI* >> RDI* >> DA1 >> DA2 >> DA3 >> DA4 >> DA5 >> DA6.
*FREE and TECH FREE share these alarms. Settings made when in one mode can be changed while in the other mode..
Due to space limitations, settings are viewed by accessing individual alarm Set screens.
• S (< 2 sec) - to access the Menu while the pointer icon ( > ) is next to SET ALARMS on the Main Menu (Fig. 131).
• A (< 2 sec) - to step down (forward) through selections.
• M (< 2 sec) - to step up (back) through selections.
• S (< 2 sec) - to access the selection indicated by the pointer icon ( > ). Example, to access Set Audible (Fig. 132).
SET AUDIBLE ALARM, information includes (Fig. 133):
> Graphics AUD ALARM.
> Graphics OFF and ON, last one saved fl ashing.
• S (2 sec) - to revert to the Set Alarms Menu without changing the setting.
• A or M (< 2 sec) - to toggle between OFF and ON.
• S (< 2 sec) - to save the setting and revert to the Set Alarms Menu.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
Setting the Audible OFF disables sounding during all alerts while operating in FREE or TECH FREE modes. It does not affect
any alarms that strike while operating in NORM or GAUG SCUBA modes.
Fig. 128 - FULL HIST DATA 2
Fig. 129 - FULL HIST DATA 3
Fig. 130 - FULL HIST DATA 4
Fig. 131 - MAIN MENU
(to access Set Alarms)
Fig. 132 - SET ALARMS MENU
(to access Set Audible)
Fig. 133 - SET AUDIBLE
53

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oceanic OCI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Oceanic OCI

Oceanic OCI Bedienungsanleitung - Deutsch - 76 seiten

Oceanic OCI Bedienungsanleitung - Französisch - 76 seiten

Oceanic OCI Bedienungsanleitung - Italienisch - 76 seiten

Oceanic OCI Bedienungsanleitung - Spanisch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info