551847
55
Zoom out
Zoom in
Vorherige Seite
1/76
Nächste Seite
55
OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r02 (9/12/13)
DD ALARMS (FREE Mode only)
There are 3 Descending Depth alarms (DD1 - DD3) that can be set only at progressively deeper depths. DD2 values must be set
deeper than DD1 and DD3 values must be set deeper than DD2.
SET DD1 ALARM, information includes (Fig. 137):
> Depth with FT (or M) icon.
> Graphics DEPTH ALARM 1 and DD1.
> Graphics OFF, ON, and SET; last saved (OFF or ON) fl ashing upon access.
A (< 2 sec) - to step forward (down) through the selections of OFF, ON, SET.
M (< 2 sec) - to step back (up) through the selections.
S (2 sec) - to step back to the Set Alarms Menu.
S (< 2 sec) - to save the selection.
> If OFF or ON is saved, operation will revert to the Set Alarms Menu.
> If SET is saved, the Depth digits will fl ash.
S (2 sec) - to step back to SET fl ashing.
A (hold) - to scroll upward through the Depth set points 16/sec from 30 to 330 FT (3 to 100 M) in increments of 1 FT (1 M).
A (< 2 sec) - to step upward through the Depth set points one at a time.
M (< 2 sec) - to step back through the Depth set points one at a time.
S (< 2 sec) - to save the setting and fl ash the graphic SET allowing ON or OFF to be selected/saved.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
SET DD2 & DD3 ALARMS, similar to Set DD1 Alarm.
> If DD2 is not set for a Depth that is deeper than DD1 and you attempt to turn DD2 ON, a message (Fig. 138) will be
displayed for 5 seconds and operation will revert to the FREE Set Alarms Menu. DD3 is similar.
-------------------------------------------------------
DA ALARMS (TECH FREE Mode only)
There are 6 Descending/Ascending Depth alarms (DA1 - DA6) that can be set without restrictions. They operate without restric-
tions during ascents as well as during descents. Each alarm sounds for the number of beeps set and sets of beeps set when the
depth set is reached during descents and/or ascents.
SET DA1 DEPTH ALARM, information includes (Fig. 139A):
> Depth with FT (or M) icon.
> Graphics DEPTH ALARM 1 and DA1.
> Graphics OFF, ON, and SET; last saved (OFF or ON) fl ashing upon access.
A (< 2 sec) - to step forward (down) through the selections of OFF, ON, SET.
M (< 2 sec) - to step back (up) through the selections.
S (2 sec) - to step back to the Set Alarms Menu.
S (< 2 sec) - to save the selection.
> If OFF or ON is selected, operation will revert to the Set Alarms Menu.
> If SET is selected, the Depth digits will fl ash.
S (2 sec) - to step back to SET fl ashing.
A (hold) - to scroll upward through the Depth set points 16/sec from 10 to 495 FT (3 to 150 M) in increments of 1 FT (1 M).
A (< 2 sec) - to step upward through the Depth set points one at a time.
M (< 2 sec) - to step back through the Depth set points one at a time.
S (< 2 sec) - to save the setting and display the Set DA1 Audible screen.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
SET DA1 AUDIBLE ALARM, information includes (Fig. 139B):
> Depth set with FT (or M) icon.
> Graphic BEEPS - with the number of beeps (1 to 10), fl ashing upon access.
> Graphic TIMES - with the number of times the beeps are to repeat (1, 2, or 3).
> Graphics DA1 and Aud.
S (2 sec) - to step back to the Set Depth screen with the Depth digits fl ashing.
A (< 2 sec) - to step upward through the Beep set points from 1 to 10 one at a time.
M (< 2 sec) - to step back through the Beep set points one at a time.
S (< 2 sec) - to save the Beep setting and fl ash the Times digit.
S (2 sec) - to step back to the Beep digits fl ashing.
A (< 2 sec) - to step upward through the Times set points from 1 to 3 one at a time.
M (< 2 sec) - to step back through the Times set points one at a time.
S (< 2 sec) - to save the Audible Beep/Times setting and revert to the Set Depth Alarm screen with the graphic SET fl ashing
allowing ON or OFF to be selected/saved.
• M (2 sec), or 2 min of no button action, - to revert to the Surface Main.
SET DA2 to DA6 ALARMS, similar to Set DA1 Depth and Audible Alarm.
Fig. 137 - SET DD ALARM
Fig. 138 - SET DD MESSAGE
Fig. 139A - SET DA DEPTH
Fig. 139B - SET DA AUDIBLE
55

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oceanic OCI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Oceanic OCI

Oceanic OCI Bedienungsanleitung - Deutsch - 76 seiten

Oceanic OCI Bedienungsanleitung - Französisch - 76 seiten

Oceanic OCI Bedienungsanleitung - Italienisch - 76 seiten

Oceanic OCI Bedienungsanleitung - Spanisch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info