812264
83
Zoom out
Zoom in
Vorherige Seite
1/160
Nächste Seite
Operating manual
for the user
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0
EN
Attention: the switching times must always relate to one day, i.e.
a switching time may not exceed the 24 hour limit. Switching on
before midnight and switching o after midnight cannot be recog-
nised by the software. If a switching time of more than 24 hours
should be dened, then a switch-o time of 23:59 must be entered
for the rst day, with a switch-on time of 0:00 for the following day.
3 dierent switching pairs can be dened for each block of days or
week day. If a target temperature is desired, select the eld after the
time pair (for Automatic” operating mode only) and then save.
Temperature range which can be set: 10 °C – 40 °C
or no temperature (---)
Factory setting: ---
“DATE/TIME” display
Time zone offset
Summer time offset is done automatically
next
.07.2021
1h
17:10
20
Fig. 3.27 Touch control panel – Setting the date and time
The change can be made by selecting the appropriate number eld.
CHILD LOCK” display
The “Child lock” can be activated in order to prevent unintentional changes
on the touch display. A lock appears as a symbol in the top right of the
display. The child lock is activated by pressing the time for 3 seconds. The
function is deactivated by repeatedly pressing the button.
Ready
15:32
AUTO mode
Desired °C
Actual °C
17
25
Party
Fig. 3.28 Touch control panel – Child lock
“INFORMATION” display
07:12
SW Version
Service
op.hours
Ext. request
2.02.17L6
2000h
0h
off
Fig. 3.29 Touch control panel – Displaying information
You can nd the following information in this display:
ū The current software version (e.g. 2.02.17 L6)
ū Time to next service. The pellet replace must be serviced at regu-
lar intervals. A service is automatically requested after 2000 operating
hours. Call a service technician to carry out the service. The “Carry out
service” notication continues to appear until the service technician
carries out the service and resets the notication in the service menu.
ū Operating hours counter
ū External requirements
ū An external room thermostat can be connected as an “external re-
quirement”. Since the internal room temperature sensor is also
still connected, the signal which switches first is used for regula-
tion. If the target temperature should be specified via the external
room thermostat, then the room temperature which can be set in
“Automatic” mode must be set to the maximum value (40 °C).
ū This display can be used to check whether the external room ther-
mostat has been connected correctly and is assuming regulation
of the pellet replace. “On” or “O” must be shown on the display
when adjusting the room temperature to higher or lower than
the current room temperature on the room thermostat.
ū If no external components are connected, the “On” is always
displayed.
Operating keys in the “Information display
SYSTEM INFO
Shows the most recent error messages
CURRENT INFORMATION
Display:
- Flame temperature
- Output stage
- Induced draft fan speed
- Vacuum
SERVICE MENU
Password protected area for service technicians
(Note: the specialist dealer can obtain the password for the
service menu from Olsberg customer service).
We reserve the right to make technical changes
83
78-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 8378-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 83 11.04.2023 14:41:5911.04.2023 14:41:59
83

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Olsberg ARINA 2.0 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info