707624
15
Zoom out
Zoom in
Vorherige Seite
1/44
Nächste Seite
15
170
1087
400
281 312 312
min 172
1
1
1
2
3
3
4
Fig. 5 Wall bracket
1 Fastening holes for wall bracket
2 Air inlet duct
3 Fastening bolts M12
4 Adjusting screws for alignment
and fold it out of the wall bracket.
– Break the cover for the rear stove pipe connection
out of the wall bracket.
Fold back the thermal insulation and fasten with
the brackets.
Through the hole of the broken-out cover, cut out
the hole for the rear stove pipe connection in the
thermal insulation.
The combustion air connection for room air inde-
pendent operation can be executed either to the rear
or below. The device is delivered pre-assembled for
the rear connection.
Proceed as follows for a bottom connection:
Pull out the drawer under the combustion chamber
door and lift it out.
Break the lower cover out of the arched oor of the
device.
Swap the rear connection duct and the lower seal-
ing cover.
For room air dependent operation:
Pull out the drawer under the combustion chamber
door and lift it out.
Unscrew the lower sealing cover in the device.
Determine the installation location for the stove.
Objects made of ammable materials must not be
present or be placed in the radiation area of the
stove to a distance of 80 cm, measured from the
view pane of the combustion chamber door.
Minimum distance to ammable or bearing walls:
lateral 17 cm
Install the pipe lining (customer-provided) in the
chimney. For the top stove pipe connection, the con-
nection height can be individually determined, how-
ever it should not exceed 1.5 m from the connec-
tion duct. For the connection height for the rear stove
pipe connection see chapter “Technical data”. There
should be no ammable material within a 20 cm cir-
cle around the stove pipe, for the passage through
structural components made of ammable materials.
Align the wall bracket as a template at the desired
position on the wall with a spirit level, hold it in place
and mark the positions of the 6 fastening holes (see
Fig. 5).
Attention: When using the recommended fastening
system in vertical coring brick, drill the 6 fastening
holes through turning, without impact.
For connection of room air independent operation
with air supply from the rear, the air inlet duct on the
wall bracket must be sealed with silicone on the wall.
Pre-mount the wall bracket with the suitable fasten-
ing system and the provided D=34 washers for M10
screws, align it using a spirit level and screw it tight
against the wall.
Lift the stove onto the skids of the wall bracket.
Slide and align the stove in front of the wall brack-
et in such a manner that the stove pipe ts into the
pipe lining. Connect the stove pipe at both connec-
tion points with stove putty so that the stove pipe is
permanently sealed.
The stove pipe connections must be sealed. The
stove pipe must not project into the chimney.
If needed the device can be aligned in the skids
(Fig. 5) with the adjusting screws.
Bolt the stove to the wall bracket with the 4 previ-
ously dismounted washers and M12 fastening nuts.
If provided, mount the OEC. To do this, pull out the
drawer under the combustion chamber door and lift
it out.
Route the cables, OEC power connection and OEC
temperature sensor, lower right in the oor space of
the device, behind the set up sheet metal clips so
that the cables are not caught by the drawer.
Mount the side cladding.
Fit the cover hood back on and only screw it on the
front.
Bear in mind that on partition walls in accordance
with test specication EN 13240, the temperature
of 85°C can be reached, and with light wallpaper
or similar combustible construction materials, this
can result in colour changes.
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Olsberg Turia Lina Compact wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info