To enable / disable alarms:
1. Press desired area to activate.
2. Press to display set HI / LO alarm.
3. Press to turn alarm on or off.
NOTE
- - indicates alarm is not set / disabled.
NOTE
Clock alarm sound is different from weather alarms to allow for easy
differentiation by user.
To silence any alarm:
Press anywhere on the touch panel.
OR
The alarm automatically turns off after 2 minutes.
NOTE
When alarm is on, the channel of triggered alarm will be flashed and alarm
sound lasts for 2 minutes.
BACKLIGHT
Press anywhere on the touch panel to activate the backlight for 8 seconds.
OR
If the main unit is powered by power adapter, switch the
LIGHT to ON in the main
unit compartment. The light will be on until you switch it OFF.
NOTE
You need to take off the battery compartment cover to do switching.
RESET
Main unit:
Press RESET to return to the default settings.
NOTE
You need to take off the battery compartment
cover to do switching.
Transmitter box:
Press RESET to remove the record of the calibrated
wind direction.
MAINTAINANCE
Each sensor of this kit has a durable plastic casing that should retain its luster for
many years. It is better to do regular maintenance to keep the sensors with high
accuracy every half year. Do cleaning the casing only with a soft cloth slightly
dampened with water or a mild soap. Please use screw drivers or wrench to take
some parts off if necessary.
Electrical storms can sometimes cause power surges harmful to electronic
equipment. For your own safety, take caution when using the main unit or doing
maintenance during storms.
TO MAINTAIN THE THERMO/HYGRO SENSOR
1. Remove the rain collector from the rain gauge.
2.
Unscrew the three type B screws from the rain gauge.
3. Unscrew the three screws from the bottom of
the thermo/hygro sensor casing.
4. Clean the casing excluding the one with sensor
by water, and then remove the dust around the
sensor carefully.
5. Install all the parts until they are entirely dried.
NOTE
If the temperature and humidity readings are
still strange and inaccurate, you need to consider
replacing this sensor, please contacting our customer service for the details.
TROUBLE SHOOTING
Problem Symptom Remedy
Barometer Strange readings Check altitude setting on the main unit.
Wind sensor No updates of the
wind direction
Check the wind vane.
Display dashes on
main unit
1. Check the connections.
2. Check the channel setting.
3. Check the pairing successful or not.
Rain sensor No readings 1. Check the cable tie on the tipping
bucket to be cut away or not.
2. Check the balance indicator.
3. Check the plastic filter in rain collector.
4. Check the connections.
Strange readings 1. Check the plastic filter in the rain collector.
2. Check the balance indicator.
Tem p/ h y g r o
sensor
Display dashes 1. Check the connections.
2. Check the pairing.
3. Check the channel setting.
No outdoor temp/
hygro readings
1. Check the rechargeable battery in
transmitter box.
2. Check the power adapter connection
and main unit batteries status.
3. Do maintenance for the sensor.
Calendar Strange date /
month
1. Change language.
2. Check the calendar setting.
Clock Cannot adjust
clock
Disable radio-controlled clock.
Cannot
auto-synchronize
1. Check batteries status.
2. Reset the main unit.
3. Manually activate radio controlled clock.
Sunrise/
Sunset
Strange readings 1. Set longitude/latitude.
2. Check the daylight saving time setting.
Transmitter
box
LED light(s) do not
flash
1. Check the switch.
2. Check the polarity of the
rechargeable battery.
3. Check the connection of the solar panel.
Sensors
pairing
Time is too long 1. Adjust the antennas to be parallel.
2. Reset the pairing switch (switch off
then on again).
PRECAUTIONS
Do not subject the unit to excessive force, shock, dust, temperature or humidity.
Do not cover the ventilation holes with any items such as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid over it, dry it immediately
with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive materials.
Do not tamper with the unit’s internal components. This invalidates the warranty.
Only use fresh batteries. Do not mix new and old batteries.
Images shown in this manual may differ from the actual display.
When disposing of this product, ensure it is collected separately for special treatment.
Placement of this product on certain types of wood may result in damage to its
finish for which Oregon Scientific will not be responsible. Consult the furniture
manufacturer’s care instructions for information.
The contents of this manual may not be reproduced without the permission of
the manufacturer.
Do not dispose old batteries as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
Please note that some units are equipped with a battery safety strip. Remove
the strip from the battery compartment before first use.
NOTE
The technical specifications for this product and the contents of the user
manual are subject to change without notice.
RESET KEY
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Oregon Scientific WMR300A wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info