Commissioning / Possible applications / After initial use
After initial use / Maintenance / Cleaning and care / Troubleshooting
Be careful when putting down
the device. Always put down the equipment so
it does not come into contact with the trigger.
This could potentially result in accidental activa-
tion of the equipment, which again could result
in hazards.
Maintenance
ATTENTION! All maintenance must be per-
formed by trained individuals. Following the
specified maintenance instructions ensures a
long service life and proper operation of this
quality product.
Disconnect equipment from the compressed air
source when performing maintenance and care.
Check the condition of wear and tear items
and accessories with every maintenance.
Note: Daily cleaning and regular lubrication
are absolutely required for smooth operation.
Only use special tool oil.
No maintenance is required beyond the above
mentioned lubrication and cleaning.
Cleaning and Care
Only use a dry cloth to clean the multitool.
Never clean with liquids such as petrol, sol-
vents or water.
Do not allow liquids to enter the equipment.
Use a vacuum cleaner to remove abrasive dust
or sawing debris from the equipment.
For oiling you may use one of the follow-
ing options
Note: If available, you may use an in-line a line
oiler, -trap or an entire maintenance unit as shown
above. We highly recommend using such mainte-
nance accessories.
a) via oil-mist lubricator
A complete maintenance unit includes an oil-mist
lubricator and is attached to the compressor
b) via line lubricator
A line lubricator is installed within close proxim-
ity of the tool (approx. 50 cm away) which ad-
equately supplies the equipment with oil.
c) manually
If your equipment (or your compressed air sys-
tem) features neither a maintenance unit nor a
line lubricator you must add 3–5 drops of oil
to the compressed air connection before each
use. If the air tool has not been used for several
days you must add 5–10 drops of oil to the
compressed air connection before powering
on the equipment.
Always store your air tools / equipment and ac-
cessories in dry locations.
Troubleshooting
Note: Regular lubrication is imperative to ensure
the longest possible life for your compressed air de-
vice. We recommend continuous lubrication via in-
line oil-mist equipment.
Fault Reduced performance
Cause Solution
1. Insufficient pres-
sure
Check all connections and
verify your compressor is
supplying sufficient pressure.
2. Clogged line Clean the line.
3. Improper lubri-
cation or insufficient
lubricant
Lubricate equipment as in-
structed.
4. Blunt or dam-
aged accessory
Replace accessory.
5. Leak / Leaking
connection
Use teflon tape or replace
the defective part.
6. Contaminated
mechanism
Have your equipment
cleaned by a qualified
technician.
73791_Druckluft-Multitool_content_LB1 (nur NL).indd 41 11.05.12 17:56
41

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Parkside IAN 73791 PDMT 6.2 A1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info