123
installation
The appliance can be connected in the following ways:
1 phase connection (1 1N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c.
Install connecting bridges between connection points 1-2 and 4-5.
Your group must be protected by a fuse of at least 32 A. The connecting power
cable must have a minimum core cross section of 6 mm
2
.
2 lives with 2 neutrals connection (2 2N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c. There may be a voltage of
0 V between the phases if they are connected to the same phase in the meter
cupboard but also 400 V if they are connected to 2 different phases. Your
groups must be fused with at least 16 A (2x). The connecting power cable must
have a minimum core cross section of 2,5 mm
2
.
122
installation
Electrical connection
For the connection, use an approved cable, in accordance with the regulations.
The cable casing should be of rubber.
There is a label on the underside of the appliance with the wiring diagrams. The
connection terminals are accessible once you have opened the junction box on
the underneath. The junction box cover can be opened with a screwdriver.
If you want to make a fixed connection, make sure that a multi-polar switch with
a contact separation of at least 3 mm is fitted in the supply line.
Power setting table
Type of hob IDK650
Induction x
Eelctrical connection
230 V - 50 Hz x
Maximum power cooking zones
Front left 3000 W
Rear left 2000 W
Rear right 2800 W
Front right 2800 W
power connection
L1 3000 W
L2 2800 W
Total power connection 5800 W