127
installation
Ventilation
The electronics in the appliance
require cooling. The ventilation
openings are located on the underside
of the appliance. It must be possible
for cool air to be drawn in through
these openings. The appliance is fitted
with outlet openings at the front and
bottom.
The kitchen unit will require a few modifications to allow optimum cooling of
the hob.
Above drawer or fixed panel
Saw out the ventilation openings (min.
100 cm
2
). Ventilation is via plinth and
rear of cupboard.
Do not allow the ventilation openings
on the underside of the appliance to
be blocked by a drawer.
Where there is a drawer, a gap of at
least 560 x 6 mm should be made at
the front. The distance between drawer
A and the hob should be a minimum of
10 mm.
No extra modifications for ventilation
need be made where there is a fixed
panel.
min.
min.
126
installation
Building in
Cut opening in worktop
Saw the opening in the worktop. This should be done very accurately (see
table). Also saw out any partitions that may be present. The distance from the
saw line to the rear wall and/or side wall is indicated in the table.
Table:
Space to be left free around the appliance:
Type of hob
IDK650
Appliance width x depth
602 x 512 mm
Installation height from top of worktop
48 mm
Cut out dimensions width x depth
560 x 490 mm
Distance from saw line to rear wall
Minimal 50 mm
Distance from appliance to side wall
Minimal 40 mm
min. 600 mm
min. 650 mm
min. 450 mm
min. 40 mm
min. 40 mm