779205
4
Zoom out
Zoom in
Vorherige Seite
1/13
Nächste Seite
6
LEGEND
GENERAL SAFETY INFORMATION FOR THE USE OF ELECTRICAL DEVICES:
To avoid injury from re or electric shock, please make sure to follow these safety instructions when using the device. Please
read the instructions carefully and make sure that you have understood them well. Keep the manual at hand to be able to
read it again at any time. Always use grounded power outlets providing an adequate voltage (as indicated on the device). If
you have any doubt, let an electrician check that your outlet is properly grounded. Never use a damaged power cable. Do not
use the device in damp or wet environment, or if your hands or body are damp or wet. Protect the device from sunlight. Use
the device in a protected environment to avoid damaging the equipment or endangering others. Make sure the device can
cool down properly and avoid placing it too close to other heat-producing devices. Before cleaning, always unplug the device.
Use a soft damp cloth for cleaning. Avoid using detergents and make sure that no liquid enters the device. The inner elements
of this device don’t require any maintenance from the user. An unauthorized opening of the device may void the guarantee.
SAFETY GUIDELINES
1. Please read and understand these instructions carefully before operating the device! Please observe the safety
guidelines carefully in order to prevent any damage due to improper use!
2. Please keep this manual at hand for future reference. If the device is handed over to third parties, this manual must
be handed over too.
3. Only use this device indoors and for its intended use.
4. The guarantee does not cover damages resulting from improper use or operation.
5. Before rst use, ensure that the voltage and current requirements of the device match the available power supply.
6. This device should not be used by persons (including children) with limited physical, sensory or mental aptitude,
or lacking the necessary experience and/or knowledge unless they are supervised by a qualied person or have
received safety instructions from this person.
7. ELECTRICAL SHOCK HAZARD! Do not attempt to repair the device yourself. In case of device failure, repair must
be done by a qualied professional.
8. Please check the main plug and power cable regularly. If the power cable is damaged, it has to be replaced by the
manufacturer or its customer service or another qualied person, in order to prevent hazards.
9. Prevent damages to the power cable by avoiding squeezing, bending or rubbing on sharp edges and keep it away from
hot surfaces and open ames.
10. CAUTION DANGER TO LIFE! During cleaning, never immerse the device in water or other liquids. Never put the
device under running water or pour other liquids on it. Never pour / dispense liquids over the device. If any liquid
should get inside the device, immediately unplug it and contact the service team.
11. Don’t open the device under any circumstances.
12. Ensure sufcient air circulation. The device should be placed over 10cm away from walls and other electrical devices.
Ventilate well the working area.
13. Do not place the device close to combustible materials.
14. During rst use, the heating element might produce some smoke. This is absolutely normal. Just ensure sufcient
ventilation so that that the smoke doesn’t accumulate in the room.
15. Some parts of the device can get extremely hot. To avoid any injury, be careful when you touch the device.
16. Never leave the device and its packaging unattended.
17. Clean the device regularly to avoid a durable encrustation of dirt.
Please read this user manual carefully.
Caution! Risk of re or explosion.
Caution! Contact with hot surfaces may cause burns
7
1
TECHNICAL DATA
Product name High-temp Sterilizer
Model HTS-80
Art. No. 4101
Rated voltage [V] / Frequency [Hz] 230 V / 50 Hz
Temperature [°C] 250
Power [W] 80
PURPOSE
This high-temperature steriliser is a device designed for the quick sterilisation of beauty tools and accessories (such as nail
clippers, tweezers, etc.) as well as other small metal tools at high temperature. Quartz balls maintain a high temperature and
keep the tools and accessories in place during the sterilisation process.
In case of damage resulting from an improper use of the device, the user shall assume all liability.
BEFORE FIRST USE
On receipt of the parcel, make sure the packaging is undamaged before opening it. If the packaging is damaged, please contact
your transport company and distributor within 3 days. Be as specic as possible when describing the damages. Do not turn
the package upside down! When transporting the package, please ensure that it is kept horizontal and stable. The packaging
materials (cardboard, plastic straps, polyurethane foam) should be kept at hand, so that the device can be sent back to the
service center, if needed, in the best conditions!
ENVIRONMENT OF USE
The room temperature must not be higher than 45°C and the relative humidity should be under 85%. Keep the device away
from hot surfaces. Operate the device on at, stable, clean, refractory and dry surfaces, out of the reach of children and
people with mental disabilities. Make sure that the power outlet is always within reach. The power outlet must be properly
grounded and match the technical requirements of the device.
OPERATING PRINCIPLE
1
2
3
4
5
6
1. main switch
2. timer switch button
3. LCD display
4. sterilisation chamber
5. chamber lid
6. quartz balls
CONNECTING / STARTING
Do not switch the device on if the chamber is empty put the quartz balls inside the chamber. Make sure that the main
switch is in the OFF position. Plug the power cord into the outlet. Turn the device on with the main switch: the display shows
„8.8.“, followed by „——“. Press the timer button (TIMER), the display now shows „15“ and the device starts its 15-minute
heating process. The remaining heating time is counted down on the display. Three short beeps indicate that the heating
process is over: the display shows „0.0.“ The steriliser is now ready for use.
USER MANUAL
Rev. 08.10.2018Rev. 08.10.2018
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Physa HTS-80 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info