POWX075740DB EN
Copyright © 2022 VARO P a g e | 10 www.varo.com
9.14 Replacing the saw blade (Fig. 4)
Disconnect the tool from the outlet before working on the saw blade.
Wait a while before touching the saw blade. It can be very hot.
The teeth of the saw blade are very sharp.
▪ Swing the machine head upwards.
▪ Loosen the cover plate screw (A), but do not remove this screw from the tool.
▪ Lift and hold up the lower blade guard to expose the threaded blade bolt
▪ Press the saw shaft lock (24) with one hand while positioning the Allen key on the flange
bolt with the other hand. The saw shaft lock (24) engages after no more than one rotation.
▪ Now, using a little more force, slacken the flange screw in the clockwise direction.
▪ Turn the flange screw right out and remove the external flange.
▪ Take the blade (2) of the inner flange and pull out down wards.
▪ Carefully clean the flange screw, outer flange and inner flange.
▪ Fit and fasten the new saw blade (2) in reverse order.
▪ Important! The cutting angle of the teeth, in other words the direction of rotation of the saw
blade (2) must coincide with the direction of the arrow on the housing.
▪ Check to make sure that all safety devices are properly mounted and in good working
condition before you begin working with the saw again. Important! Every time that you
change the saw blade, check to see that it spins freely in the table insert (8) in both
perpendicular and 45° angle settings.
When replacing the saw blade, you can tighten the slide bar with the
locking knob (20).
10 CLEANING AND MAINTENANCE
Before performing any work on the equipment, pull the power plug.
10.1 Cleaning
▪ Regularly clean the machine housing with a soft cloth, preferably after each use.
▪ If the dirt does not come off use a soft cloth moistened with soapy water.
▪ Never use solvents such as petrol, alcohol, ammonia water, etc. These solvents may
damage the plastic parts.
Make sure no water can reach the inside of the power tool!
10.2 Connecting cable
If the connecting cable (or mains plug) is damaged, it must be replaced. Replacement of the
connecting cable should only be carried out by a qualified specialist (qualified electrician).
11 TECHNICAL DATA