8 Working
8.1 AUTOClean - Cleaning the
main lter
To maintain a constant suction power when
extracting ne dust, you can adjust the
frequency of the automatic [1-7] cleaning
system in in nite variables using the rotary
knob. Always use the automatic cleaning
system in combination with a disposal bag
(in line with dust class ‘M’ requirements).
Always use a lter bag when the cleaning
function is switched off (except for when
wet vacuuming).
Before performing wet extraction
tasks or working with a lter bag, set
the rotary knob to position 0.
For large amounts of dust, optimum opera-
tion is only possible if dedusting is switched
on.
Manual cleaning
If the suction power decreases, clean-
ing can be started manually by turn-
ing the switch [1-9] to the AC symbol
positioned on either side of the switch.
We recommend cleaning the main lter
completely if severely clogged:
Set the suction power adjuster [1-8] to the
maximum setting.
Cover the end of the nozzle or suction hose
with your hand for 10 seconds.
Turn the switch to the [1-9] AC symbol.
In intensive applications that generate ad-
herent dust, it may be necessary to clean
the lter element mechanically under cer-
tain circumstances (extract). Wear a dust
mask!
8.2 Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
Use a lter or disposal bag when extract-
ing hazardous materials!
Do not use the machine if the volumetric
ow monitoring function is inactive.
Observe the following when extracting
dust generated by operating electric power
tools:
If the exhaust air is discharged back into
the room, the air renewal rate L within
the room must be suf cient. The volume of
air discharged back into the room must not
exceed 50% of the fresh air volume ow
(room volume V
R
x air renewal rate L
W
).
Observe all the relevant regional regula-
tions.
Remember: A moist main filter clogs
more quickly when extracting dry materi-
als. Therefore, dry the main lter before
extracting dust or replace the damp lter
with a dry one.
7.8 Volumetric ow monitoring
An acoustic warning signal sounds if the air speed in the suction hose falls below 20 m/s
(for dust class M only).
Possible causes Solution
Value set on the suction power adjuster
[1-8] is too low.
Set the suction power adjuster to a higher
value (see Chapter 7.3).
The rotary knob [1-10] is not set to the
hose diameter setting (only for dust
class M).
Set the correct hose diameter.
Suction hose blocked or kinked. Remove blockage or kink.
Filter bag/disposal bag full. Insert a new lter bag (see Chapter 7.6).
Filter element clogged. Clean lter element (see Chapter 8.1).
Change the lter element (see Chapter 9.1).
Monitoring electronics malfunction. Send to a PROTOOL service workshop for
repair.
Wet extraction. Functional reliability not affected, no
actions required.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Protool VCP 480E-M wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info