599858
3
Zoom out
Zoom in
Vorherige Seite
1/5
Nächste Seite
Ref No.022011
Important Notes
Care and cleaning
The probe is the most delicate part of the thermometer. Use with care when cleaning the lens to avoid damage.
a. After the measurement, please use the cotton swab with the Alcohol (70% concentration) to clean the inside of the probe,
including lens and metal parts.
b. Allow the probe to fully dry for at least 1 minute.
c.
Storage temperature range: It should be stored at room temperature between -20~+50°C,
RH85%
d .Keep the unit dry and away from any liquids and direct sunlight.
e. The Probe should not be submerged into liquids.
* Note: Please check the device if damaged once it falls. If you can’t make sure of it ,please send the
complete device to the nearest retailer for recalibration.
Holding the thermometer too long may cause a higher ambient temperature reading of the probe.
This could make the body temperature measurement lower than usual.
Battery replacement
1
Open the battery cover: Insert a pointed object, such as a pen, into battery cover pick hole.
At the same time, use thumb to push battery cover out.
2
Hold the device and flip the battery out with a small screwdriver
3
Insert the new battery under the metal hook on the left side and press the right side of the battery
down until you hear a click.
4
Replace the battery cover
Keep the battery away from children. (This device is supplied with one lithium cell (CR2032x1).)
The positive (+) side up and the negative (-) side pointed down.
Trouble shooting:
Error Message
Problem Solution
Error 5~9, the system is not functioning properly.
Unload the battery, wait for 1 minute and repower it. If the message
reappears, contact the retailer for service.
Measurement before device stabilization. Wait until all the icons stops flashing.
The device showing a rapid ambient temperature change.
The ambient temperature is not within the range between 10
o
C and 40
o
C (50
o
F
~104
o
F).
Allow the thermometer to rest in a room for at least 30 minutes at room
temperature: 10
o
C and 40
o
C (50
o
F ~104
o
F).
(1) In Ear/Forehead mode: Temperature taken is higher than +42.2
o
C (108°F)
(2) In Scan mode: Temperature taken is higher than +80
o
C (176°F)
(1) In Ear/Forehead mode: Temperature taken is lower than +34
o
C (93.2°F)
(2) In Scan mode: Temperature taken is lower than –22
o
C (-7.6°F)
Please select the target within specifications. If a malfunction still exists,
please contact the nearest retailer.
Device cannot be powered on to the ready stage. Change with a new battery.
Warranty:
Warranty :12 months
Manufacture Dateas the serial number( please open the battery cover, it is shown on the inside of the device.)
Ex.SN:E912A000001, the first “E” is External, the second number “9” is the manufacture year 2009, the third and the fourth number “12” is the manufacture month, the
others is the serial number.
Note: Suggest that the device is performed the re-test for accuracy after 3 years. Please send the complete device to the dealers or nearest service address.
However, if this device is used according to the operation instruction, periodic re-calibration is not required.
Please read the instructions for use BF type applied part
Radiant Innovation Inc.
Http://www.radiantek.com.tw
Add: 1F, No.3, Industrial East 9
th
Road,
Science-Based Industrial Park, HsinChu, Taiwan 300.
Medical Technology Promedt Consulting GmbH
Add: Altenhofstrasse 80, D-66386 St. Ingbert, Germany
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Radiant TH52Z wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info