14
Warning : Before changing saw blades always turn off the main switch (fig.6.1).
The maximum diameter of the saw blades used on the machine is 300 mm.
Push the sliding table to the rear and open the saw cover (fig.8) and loosen the 2 wingnuts
underneath the sliding table handle plate, slide the plate open to the left as can bee seen in
the figure 7.
Raise the main saw blade to its highest position and put the saw nut spanner onto the saw
arbor nut.
Put the locking pin in the opening of the saw table and turn the arbor with the spanner
untill the locking pin engages in the hole in the saw arbor pulley.
Now unlock the nut.Warning: the nut has a left thread, so loosen by turning the nut in the
anti-clockwise direction. Before fitting the new saw blade ensure the blade and flanges are
clean. This prevents wobbling of the sawblade.
Never forget, after the saw arbor nut has been tightened, to remove the locking pin
from the pulley before starting up the motor.
Handle saw blades with care, to avoid serious cuts and injuries.
The use off HSS saw blades is prohibited by CE Regulations: use only carbide tipped
saw blades.
The motor can not be started-up as long as the lower saw blade cover plate is open:
close it!