532741
6
Zoom out
Zoom in
Vorherige Seite
1/32
Nächste Seite
1
WARNING NOTICE
SANICOM
®
1 is a lifting pump for wastewater used in com-
mercial applications (restaurants, hairdressing salons, the
catering industry etc.). The unit operates automatically, has
a high performance level, and is safe and reliable, provided
all the rules for installation and maintenance in this notice
are strictly followed.
Especially those indicated by:
«
» Failure to comply with this instruction could endanger
the safety of persons,
«
» Indication that a risk of electrical
origin exists,
«
» Electrical installation must be carried out by a
professional electrician.
«ATTENTION» Failure to comply with this instruction could
endanger the safe functioning of the apparatus.
For any additional information, please contact our customer
service department.
HOW IT WORKS
SANICOM
®
1 contains 1 pump. The tank is equipped with a
sensor tube which controls the automatic activation of the
motor when waste enters the unit.
As soon as the waste enters the tank, the pump starts.
2
LIST OF PARTS SUPPLIED
3
DIMENSIONS
4
SANICOM
®
1 TECHNICAL DATA AND APPLICATION
Application
Sinks, washing machine,
dishwasher or shower*
or bath*
Type P100
Maximum vertical pumping height 10 m
Voltage 220 240 V
Frequency 50 Hz
Maximum power consumption 1300 W
Maximum current consumption 6 A
Electrical class I
Protection index IP44
Max temp with intermittent functioning 90°
Net weight 10 kg
* In the case of bath or shower tray, make sure the waste
traps are raised 19 cm above floor level.
CAUTION: 1. All applications other than those described in
this notice are prohibited.
2. Do not exceed an incoming flow rate greater
than 80% of the flow rate stated on the design
curve
5
in any of the apparatus.
5
PERFORMANCE CURVES
6
VERTICAL/HORIZONTAL PUMPING
7
INSTALLATION
The pump has securing devices, preventing it from turning
or moving.
7a
FITTING
1- Warning: The space in which SANICOM
®
1 is installed must
be large enough to leave at least 600mm around the unit
for easy maintenance. This space must be well lit, ventila-
ted, and must never be immersed in water and must be
protected from frost.
2- Isolation valves should be fitted to the inlet pipework and
discharge pipework to isolate the unit in case of the need
for service.
3- This evacuation pipe must be designed so as to prevent
back-flow from the sewers.
7b
CONNECTION TO SIDE INLETS
Use the flexible inlet connector
A
for side input connections.
Using a metalwork saw, saw
the desired input point, remove any burrs and then fix the
flexible inlet connector with the jubilee clip
D
.
CAUTION: In the case of an installation for drainage of
greasy wastes allow for a grease trap in front of each input
point.
Connection to the inlet can be made using a DN40
or DN50 pipe. To make a DN50 connection, cut off the end
of sleeve
A
beforehand.
7c
CONNECTION TO SANITARY WARE
To connect bathtub (or shower), make sure the waste
trap height is raised by at least 19 cm above floor level.
Connection must be made using 40 mm or 50 mm diameter
pipework, with minimum slope of 1%.
7d
CONNECTION TO SOIL AND VENT PIPE OR DRAIN
The disposal of waste from the SANICOM
®
1
can discharged
through a 32 mm diameter copper or plastic pipes (or PVC,
ABS, etc.).
Horizontal discharge pipework should maintain a 1% fall
(1cm/M) to the soil and vent pipe. If a vertical rise is
required, this must be installed at the start of the run,
before the horizontal section.
Take care that the discharge valve flap faces the direc-
tion of flow.
If the end of the discharge pipework is much lower than the
unit, install a riser pipe about 80mm long from the highest
point of the discharge run and fit an air admittance pipe on
top (capable of withstanding at least 15psi pressure.) to
break the syphon.
End the outlet pipe at the waste stack.
PLEASE NOTE: be sure to fit hoop
J
.
7e
IN CASE SERVICE IS NEEDED
Allow for a drain-off point at the bottom of the rising
waste pipe. Ensure that the unit is easily accessible for pos-
sible maintenance.
7f
ELECTRICAL CONNECTION
The electrical installation should be carried by a qualified
person.
All wiring must conform to BS7671, 1992 requirements for
electrical installation. The unit requires a 220/240 V single
phase AC 50 Hz supply (UK specification). Do not connect
the unit to a conventional plug and socket. The unit should be
connected to a fully earthed electrical supply (class 1). It must
be wired into an unswitched fused fixed wiring connector
protected by a 10 amp fuse and a residual current detector
(30 mA). This connection must be used exclusively for
supplying the SANICOM
®
1 unit.
The wires in the mains lead are coloured in accordance with
the following code:
Brown - Live
Blue - Neutral
Green/Yellow - Earth
WARNING: Ensure the electricity is turned OFF at the main
switch board before wiring to connector. All work on cable,
pressure chamber and motor should only be carried out by a
qualified SANIFLO servicing agent, as special tools are
required.
CAUTION: When the apparatus is connected up for the first
time, it will work for 5 seconds even if there is no water in
the basin. This operation acts as a manual start-up.
UK
Fully illustrated step by step instructions are
downloadable on www.saniflo.co.uk
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sanibroyeur SANICOM 1 Expert-line wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Sanibroyeur SANICOM 1 Expert-line

Sanibroyeur SANICOM 1 Expert-line Zusatzinformation - Holländisch - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info