ALARM
There is the option of connecting an alarm (light, bell) on to
the electronic circuit board (2 terminals fed with 220V). If the
motor is fed continuously (more than 5 minutes), the contact
will be made. This enables the user to carry out a check if he
wishes.
CONNECTION OF THE ALARM
Two 6.35 push on connection points are available on the
electronic circuit board (arrowed) for creating an alarm
circuit. (These connectors have a 220V, 0.5A maximum
current passing through them). To access them after turning
the power off, remove the cover then unscrew and unclip
the upper casing of the electronic box, to expose the
electronic circuit board. On this card use the point marked
E.V. and the unused neutral connection point marked N.
Use a round 2 x 0.75 mm2 wire, which must pass across
the lid of the upper casing, through the cable gland, before
being connected to the chosen alarm system.
11
USE
SANICOM
®
1 is designed for disposing of wastewater
originating from sinks, clothes washing machines,
dishwashers, showers or baths and basins.
SANICOM
®
1 can pump out hot water.
CAUTION:
1. Do not dispose of concentrated chemical products (acids,
solvents, bases, oxidants, reducers, etc.) into sanitary
ware connected to the SANICOM
®
1.
2. In the event of power failure, stop all water flow to the
appliances connected to the SANICOM
©
1.
14
WARRANTY
SANICOM
®
1 SFA is guaranteed for 2 years for labour and
parts, subject to correct installation and use of the
apparatus.
8
STANDARD
This piece of equipment complies with the EN 12050-2 stan-
dard (Lift station for effluents not containing faecal matter) and
the directives and European standards on electric safety and
electromagnetic compatibility.
ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY A
PROFESSIONAL ELECTRICIAN
10
COMMISSIONING
Once the hydraulic and electrical connections have been
made, check that the connections are tight by allowing water
to flow through each entry point used. Ensure that the pump
is working properly.
12
FIRST LEVEL TROUBLESHOOTING
REMEDY
1. Check the electrical installation.
1. Vérifier l’arrivée d’eau, sinon
voir ci-dessous
PROBABLE CAUSE
1. The appliance is not switched on
2. The cable is defective
1. Pump blocked
2. Pump jammed
3. Too much water flowing
through
PROBLEMS
• Motor does not start
• The alarm sounds
For all other intervention, disconnect the electrical current.
PROBLEM ENCOUNTERED
• Motor does not start
Pumps working constantly
• Alarm sounding
Intermittent start-up of pumps
PROBABLE CAUSE
1. Pressure reader tube kinked or
out of position
2. Electronic card defective
1. Level pressure pipe is blocked
2. Vertical discharge too high
3. Electronic card defective
1. Pump blocked
2. Pump jammed
3 Electrical problems with motor
4. Too much water flowing
through
5. Electronic card defective
1. The non-return valve broken
or leaking
2. Electronic card defective
REMEDY
1. Remove or replace the tube.
2. Consult an SFA-approved
breakdown technician.
1. Extract the level pressure pipe
unblock it.
2. Examine the appliance.
3. Consult an SFA-approved
breakdown technician.
1. IAdjust the pump which is
displaying the alarm:
Using a screwdriver, turn the
motor shaft by accessing it
through the hood.
Remove the pump and
unblock it.
If the pump revolves but does not
pump, consult an SFA-approved
breakdown technician.
5. Consult an SFA-approved
breakdown technician.
1. Clean or change the valve.
2. Consult an SFA-approved
breakdown technician.
SECONDARY TROUBLESHOOTING
ELECTRICAL INSTALLATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
13
REMOVAL
13a
REMOVING THE MOTOR
1
SWITCH THE APPLIANCE OFF (the yellow indicator light
must be out).
2
Empty the tank.
To access the anti-backflow valve:
3
Unscrew the clips and then remove the elbow (6).
4
Clean or replace the valve (8).
To remove the motor
5
Unscrew the six screws (66) torx T20.
6
Turn the motor anti-clockwise (warning: the motor may
be hot) and lift it out.
13b
REPLACING THE MOTOR
1
Locate the motor into the adaptor plate, ensure it is firmly
home and turn it clockwise until the reference marks line
up.
2
Screw in the six screws into the adaptor plate.
3
Check that the motor can turn freely using a screwdriver
into the top of the motor shaft.
ELECTRICAL INSTALLATION MUST BE CARRIED
OUT BY A PROFESSIONAL ELECTRICIAN
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sanibroyeur SANICOM 1 Expert-line wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Sanibroyeur SANICOM 1 Expert-line

Sanibroyeur SANICOM 1 Expert-line Zusatzinformation - Holländisch - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info