Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Make sure that the connection cable does not hang
on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F“.
The printing of the type designation on the connection
cable is mandatory.
AC motor
The mains voltage must be 230 V~
Extension cables up to 25 m long must have a
cross-section of 1.5 mm2.
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event of
any enquiries:
Type of current for the motor
Machine data - type plate
Machine data - type plate
Cleaning and Servicing
Pull the mains plug before any adjustments,
maintenance or repair.
m Have any work on the device that is not de-
scribed in this instruction guide performed by
a professional. Only use original parts. Allow
the device to cool off before any maintenance or
cleaning is undertaken. There is a risk of burning!
Always check the device before using it for obvi-
ous defects such as loose, worn or damaged parts,
correct the positioning of screws or other parts. Ex-
change the damaged parts.
Cleaning
Do not use any cleaning agents or solvents. Chemical
substances can etch the plastic parts of the device.
Never clean the device under running water.
Thoroughly clean the device after every use.
Clean the ventilation openings and the surface of
the device with a soft brush or cloth.
Remove chips, dust and dirt with a vacuum cleaner
if necessary.
Lubricate moving parts regularly.
Do not allow lubricants to come into contact with
switches, V-belts, pulleys and drill lifting arms.
Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
Working speeds
Ensure that you drill at the proper speed. Drill speed is
dependent on the diameter of the drill bit and the mate-
rial in question.
The table below acts as a guide for selecting the proper
speed for various materials.
Note: The drill speeds speci ed are merely sugges-
ted values.
Drill
bit Ø
Cast
iron
Steel Iron Alumi-
nium
Bronze
32550 1600 2230 9500 8000
41900 1200 1680 7200 6000
51530 955 1340 5700 4800
61270 800 1100 4800 4000
71090 680 960 4100 3400
8 960 600 840 3600 3000
9 850 530 740 3200 2650
10 765 480 670 2860 2400
11 700 435 610 2600 2170
12 640 400 560 2400 2000
13 590 370 515 2200 1840
14 545 340 480 2000 1700
16 480 300 420 1800 1500
18 425 265 370 1600 1300
20 380 240 335 1400 1200
22 350 220 305 1300 1100
25 305 190 270 1150 950
Countersinking and center-drilling
With this table drill, you can also countersink and center-
drill. Please observe that countersinking should be
performed at the lowest speed, while a high speed is
required for center-drilling.
Drilling wood
Please note that sawdust must be properly evacuated
when working with wood, as it can pose a health hazard.
Ensure that you wear a suitable dust mask when perfor-
ming work that generates dust.
Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer‘s mains connection as well as the
extension cable used must also comply with these
regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been improp-
erly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Scheppach DP18VARIO wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info