Fault Possible Cause Remedy
saw blade detachs after motor is switched off fastening nut too slack tighten M 20 left-handed fastening nut
motor fails to start a) mains fuse outage a) check mains fuse
b) faulty extension cable b)
refer to section on electrical connection, in the
operating instructions
c) faulty connections to motor or switch, brake
fails to release
c) should be checked by a qualified electrician
d) faulty motor or switch d)
see section on electrical connection, in the
operating instructions
e) saw blade protective cover open e) close saw blade protective cover
incorrect motor rotational direction a) faulty capacitor a) should be replaced by a qualified electrician
b) incorrect connection b) wall socket polarity should be changed by a
qualified electrician
no motor output, motor switches off automati-
cally
a) overload caused by dull saw blade a) install sharpened saw blade
b) thermal protection activates b) can be switched on again after cooling
period
burn marks where cut is made
on cross section
a) dull saw blade a) install sharpened saw blade
b) incorrect saw blade b) install saw blade for lengthwise cuts
c) fence not parallel to saw blade c) replace fence
d) sliding table carriage not parallel to saw
blade
d) align sliding table carriage to saw blade
reduced saw performance at full motor speed loose belt tighten belt, refer to maintenance section
workpiece jams between sawblade and fence fence does not run parallel to saw blade check fence alignment
sliding table carriage does not move a) lock has not been released a) release lock
b) guide unit is dirty b) clean guide unit
marked as H 07 RN.
Regulations require that the type designation be printed on
the connection cable.
AC Motor
The required supply voltage is 230 Volt - 50 Hz.
Extension cables up to 25 m in length must have a cross
section of 1.5 mm2; extension cables which exceed 25
m in length must have a cross section of 2.5 mm2.
The mains connection has a 16 A time delay fuse.
Three-Phase Current Motor
The 400 V / 50 Hz electric motor is designed for the S6 / 40 %
operating mode.
The required supply voltage is 400 Volt - 50 Hz.
The mains connection and extension cable must be
equipped with 5 wires = 3 P + N + PE.
Extension cables must have a cross section of no less
than 1.5 mm2.
The mains connection is fused to a maximum of 16 A.
Check the rotational direction when connecting to the
power supply or changing location: it may be necessary
to change the polarity (wall socket).
If you have questions always provide the following information:
motor manufacturer
type of current used by motor
data listed on the machine type plate
If you return the motor always send the complete drive unit
including switch.
34

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Scheppach FORSA 4.1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info