781852
23
Zoom out
Zoom in
Vorherige Seite
1/136
Nächste Seite
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
GB | 23
When connecting to the mains or relocating the ma-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary).
Turn pole inverter in the machine socket.
11. Cleaning
Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
12. Transport
For transport, the splitting knife A must be complete-
ly moved down. Slightly tilt the log splitter with handle
B on the splitting column until the machine is inclined

13. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and

Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
14. Maintenance
Attention!
Pull out the power plug before carrying out any main-
tenance work on the equipment.
When must the oil be changed?
First oil change after 50 operating hours, then every
500 operating hours.
Oil change (g. 12)
Completely retract the splitting column.
Put a container with a volume of at least 6 litres
under the splitter.
Release the oil dipstick 14.
Open the oil drain plug 12a under the oil tank so the

Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the ap-
plicable VDE and DIN provisions.
The customer‘s mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been im-
properly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN“.
The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
AC motor 230 V/ 50 Hz
Mains voltage 230 Volt / 50 Hz.
Mains voltage and extension cables must be 3-lead
= P + N + SL. - (1/N/PE).
Extension cables must have a minimum cross-sec-
tion of 1.5 mm².
Mains fuse protection is 16 A maximum.
Three-phase motor 400 V / 50 Hz
Mains voltage 400 V / 50 Hz
Mains voltage and extension cables must be 5-lead
(3P + N + SL (3/N/PE).
Extension cables must have a minimum cross-sec-
tion of 1.5 mm².
Mains fuse protection is 16 A maximum.
23

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Scheppach HL730 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info