24 GB
Repairs of the laser may only be carried out by the
laser manufacturer or an authorised representative.
Safety instructions for handling batteries
1 Always make sure that the batteries are inserted
with the correct polarity (+ and –), as indicated on
the battery.
2 Do not short-circuit batteries.
3 Do not charge non-rechargeable batteries.
4 Do not overcharge batteries!
5 Do not mix old and new batteries or batteries of
different types or manufacturers! Replace an entire
set of batteries at the same time.
6 Immediately remove used batteries from the device
and dispose of them properly!
7 Do not allow batteries to heat up!
8 Do not weld or solder directly on batteries!
9 Do not dismantle batteries!
10 Do not allow batteries to deform!
11 Do not throw batteries into re!
12 Keep batteries out of the reach of children.
13 Do not allow children to replace batteries without
supervision!
14 Do not keep batteries near re, ovens or other
sources of heat. Do not use batteries in direct sun-
light or store them in vehicles in hot weather.
15 Keep unused batteries in the original packaging and
keep them away from metal objects. Do not mix
unpacked batteries or toss them together! This can
lead to a short-circuit of the battery and thus dam-
age, burns or even the risk of re.
16 Remove batteries from the equipment when it will
not be used for an extended period of time, unless
it is for emergencies!
17 NEVER handle batteries that have leaked without
appropriate protection. If the leaked uid comes into
contact with your skin, the skin in this area should be
rinsed off under running water immediately. Always
prevent the uid from coming into contact with the
eyes and mouth. In the event of contact, please seek
immediate medical attention.
18 Clean the battery contacts and corresponding con-
tacts in the device prior to inserting the batteries:
6. Technical data
AC motor 230 - 240 V~ 50Hz
Power 1700 Watt
Operating mode S6 20% 5 Min
Idle speed n03800 / 5000 min -1
Carbide saw blade
ø 216 x ø 30 x 1,26 mm ø 216 x ø 30 x 2,8 mm
Number of teeth 40
Swivel range -45° / 0°/ +45°
Mitre cut 0° bis 45° nach left
Saw width at 90° 305 x 65 mm
Saw width at 45° 215 x 65 mm
Saw width at 2 x 45°
(double mitre cut) 215 x 36 mm
Protection class II
Weight 12,2 kg
Laser class 2
Wavelength of laser 650 nm
Laser output ≤ 1 mW
Laser module power
supply
3 x AG13
button cell
* S6, continuous operation periodic duty.
Identical duty cycles with a period at load followed
by a period at no load. Running time 5 minutes; du-
ty cycle is 20% of the running time.
The work piece must have a minimum height of 3mm
and a minimum width of 10 mm.
Make sure that the workpiece is always secured with
the clamping device.
Noise and vibration
Total vibration values determined in accordance with
EN 61029.
sound pressure level LpA 95 dB(A)
uncertainty KpA 3 dB
sound power level LWA 108 dB(A)
uncertainty KWA 3 dB
Wear hearing protection.
The effects of noise can cause a loss of hearing. Total
vibration values (vector sum - three directions) deter-
mined in accordance with EN 61029.
Vibration emission value ah2,50 m/s²
uncertainty K 1,5 m/s²
- The specied vibration value was established in ac-
cordance with a standardized testing method. It may
change according to how the electric equipment is
used and may exceed the specied value in exceptio-
nal circumstances;
- The specied vibration value can be used to compare
the equipment with other electric power tools.
- The specied vibration value can be used for initial
assessment of a harmful effect.
Warning:
The vibration emission value can vary from the speci-
ed value during the actual use of the electric tool,
depending on the type and the manner in which the
electric tool is used;
Try to minimise stress from vibrations as low as possi-
ble. Some examples of means for reducing the vibra-
tion stress are wearing gloves while using the tool and
limiting work time. In the process all parts of the operat-
ing cycle must be taken into account (such as times in
which the electric tool is switched off or time in which it
is switched on, but is not running under a load).
Residual risks
The machine has been built according to the state of
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Scheppach MS216A Kity wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info