Safety informations service/ maintenance
1. Only original parts may be used for maintenance
and accessories.
2. Replace faulty silencers.
3. Before using, always visually inspect to see that
the tools are not worn or damaged. Replace worn
or damaged elements and bolts. Keep all nuts,
bolts and screws tight to be sure the equipment is
in safe working condition.
4. Regularly check for leakage or traces of abrasion
in the fuel system, such as porous pipes, loose or
missing clamps and damage to the tank or tank
cap. Before use all defects must be repaired.
5. Before checking or adjusting the generator or the
motor, the ignition plug and the ignition wire re-
spectively must be removed to prevent acciden-
tal starting.
m WARNING!
Improper maintenance or ignoring/ not rectifying a
problem during the operation may become a source
of danger. Operate your machine only if regular-
ly maintained. Only in this way you can assume that
your device is operating safe, economical and with-
out malfunctions.
Do not clean, maintain, setup or repair the ma-
chine whilst running. Moving parts may cause
serious injuries.
Do not use fuel or other ammable solvents to clean
the equipment.
m WARNING! Vapours of fuels and solvents may ex-
plode.
Reafx the security and safety equipment after repa-
ration and maintenance work.
Keep the machine in safe work condition. Especially
check the fuel system for tightness.
Always remove any dirt from the cooling ns of the
engine.
Residual risks and accident prevention stand-
ards
Neglect of ergonomic principles
Negligent handling of personal protective equip-
ment (PPE)
Negligent handling or ommission of the personal pro-
tective equipment may cause serious injuries.
- Wear prescribed personal protection equipment.
Human behaviour, misbehaviour
For any work be fully concentrated.
m Residual risks - Cannot be entirely excluded.
18. Generating sets may only be loaded up to their
rated power under the rated ambient condition. If
generating set use is under conditions which do
not conform to the reference conditions as stipu-
lated in ISO 8528-8 and if cooling of the engine or
alternator is impaired, e.g. as a result of operation
in restricted areas, a reduction in power is neces-
sary.
19. It is necessary reduction in power due to use in
higher temperatures, altitudes and humidity as
below conditions.
Max. Working temperature: 40 °C
Max. Altitudes: 1000 m
Max. Humidity: 90 %
20. Keep the generator free of oil, dirt and other im-
purities.
21. Ensure the sound absorber and air lter work
properly. These parts serve as ame protection
in case of misre.
22. Before connecting electric leads, the appliance
must reach its full speed. Disconnect leads before
switching off the motor.
23. To prevent injury by electric shock, ensure the fuel
tank is not completely empty while electric leads
are connected.
24. The load must not exceed the power marked on
the rating label of the generator. Overloading may
result in damage to, or a shorter life of the appli-
ance.
25. Do not connect the appliance to household out-
lets. The generating set must not be connected to
other power sources, such as the power company
supply mains. In special cases where stand-by
connection to existing electrical systems is in-
tended, it shall only be performed by a qualied
electrician who has to consider the differences
between operating equipment using the public
electrical supply network and operating the gen-
erating set.
26. Stop the engine:
- whenever you leave the machine
- before refueling
27. Always close the fuel valve when the machine is
not in operation.
28. Never use the choke lever to stop the engine.
Warning! This electric tool generates an electromag-
netic eld during operation. This eld can impair ac-
tive or passive medical implants under certain condi-
tions. In order to prevent the risk of serious or deadly
injuries, we recommend that persons with medical
implants consult with their physician and the manu-
facturer of the medical implant prior to operating the
electric tool.
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Scheppach SG3400i wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info