758389
11
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
- 11 - 06/2020
Copyright © 2020, Fast ČR, a.s.
MANUAL FLUSH
We recommend that you always clean the coffee spout when you have finished
using it. It is also recommended to do this when the appliance has not been used for
an extended period of time.
1. In the stand-by mode, simultaneously press and hold down buttons B7 andB9
for 5 seconds.
2. The lights of the touch buttons will turn off. Asmall amount of water will flow out of
the spout, which will flush it out. Water will flow into the drip tray A11.
Attention:
Avoid coming into contact with hot water.
3. After finishing the manual flush, the appliance will switch back to the stand-by
mode.
DRAIN INTERNAL LINES
It is recommended to drain the internal lines when you plan on not using the
appliance for and extended period of time, before transporting it, etc.
1. In the stand-by mode, simultaneously press and hold down buttons B7 andB11
for 5 seconds.
2. Indicator B6 will start flashing.
3. Remove the water tank A1 from the appliance. Indicator B6 will be lit. This
signals that the draining of the internal lines is running.
Note:
If you press button B7 before taking out the water tank A1, you will
return back to the stand-by mode.
4. When the internal line draining process is complete, the appliance will turn off
automatically.
CLEANING THE GROUND COFFEE OUTLET
During use, ground coffee may accumulate on the walls of the ground coffee outlet
and therefore it is necessary to clean it regularly (depending on the frequency of
use).
1. Slide out and remove the service access door A7. Press the steam unit release
buttons A6 and take out the steaming unit A6 – see figure H.
2. Carefully tilt the espresso machine and using brush A12, carefully remove any dirty
material from the walls of the ground coffee outlet – see figure K.
3. After cleaning it out, insert the steaming unit A6 and the service access door A7
back in their place.
Storage
When not using the appliance for an extended period of time, disconnect the power
plug from the power socket, allow the appliance to cool down and clean it according
to the instructions provided above.
Before storing it, check that the appliance and all its accessories are thoroughly
clean and dry.
Store the appliance in a dry, clean and well-ventilated location not exposed to
extreme temperatures and out of children'sreach.
TROUBLESHOOTING
Problem Cause Solution
The appliance is not
working.
It is not connected to
apower socket.
Connect it to aworking
power socket and press
button B7 .
Check that the power cord
A5 is properly connected to
the socket in the appliance
and that the plug is properly
inserted in the power socket.
There is no response
when abutton
is pressed or the
response is delayed.
Electromagnetic interference
of the appliance is occurring.
Turn off the appliance and
turn it back on again after
several minutes.
The touch panel is soiled. Turn off the appliance,
disconnect it from the
power socket and clean the
panel using aclean, lightly
dampened cloth and then
thoroughly wipe it dry.
Coffee is not warm
enough.
Cups have not been
warmed up.
Warm up the cups.
The steaming unit A6 is
too cold.
Flush out the spout three
times before brewing coffee.
Coffee is not flowing
out the spout.
Prior to this you used the
drain internal lines function.
Press the dispensing hot
water button until water
starts flowing from the
spout.
The first cup does not
taste particularly good.
There is an insufficient
amount of ground coffee
inside the steaming unit A6.
Pour out of the first coffee
that you brewed. The next
cup will now be in order.
The coffee lacks froth. The coffee beans are not
fresh.
Use fresh coffee beans or
try using adifferent brand
of coffee.
Touch buttons do not
function properly.
The touch buttons are not
pressed properly.
It is necessary to use the
appliance from the front.
Press the bottom part of the
icon of the touch button.
The appliance heats up
for too long.
The appliance is soiled by
limescale deposits.
Descale it according to the
instructions contained in
section "Self-clean function
(self-cleaning)".
The water tank A1
is removed or it is
running out of water,
but the respective
indicator is not
signalling anything.
The area around the
connector at the bottom of
the water tank A1 is damp
or wet.
Thoroughly dry out any
moisture or water in the
vicinity of the connector.
The inner drip tray A10
is filled with alarge
amount of water.
The coffee is ground too fine,
which prevents water from
flowing through.
While the coffee grinder
is running, set acoarser
grind level.
The coffee is supplied
too slowly or
intermittently.
The coffee is ground too fine,
which prevents water from
flowing through.
While the coffee grinder
is running, set acoarser
grind level.
The insufficient coffee
beans indicator is
flashing even though
there is asufficient
amount of coffee
beans in the hopper.
The internal ground coffee
outlet is clogged.
Clean out the ground coffee
outlet of the appliance
according to the instructions
in section "Cleaning the
ground coffee outlet".
No frothed milk is
coming out of the
appliance.
The automatic milk frothing
device is dirty or is not
correctly assembled or
installed.
Clean the automatic milk
frothing device and check
that it is correctly assemble
or installed.
The holes in connecting
tube A15 are clogged.
Clean out the connecting
tube A15 according to
the instructions in section
"Everyday cleaning and
maintenance – Milk jug,
milk tube and connecting
tube".
The holes in
connecting tube A15
are clogged and it is
difficult to remove
dirty material.
The connecting tube A15
has not been cleaned out in
along time.
Leave the connecting tube
A15 submerged in hot
water for approximately one
hour and then clean out
the connecting tube A15
according to the instructions
in section |"Everyday
cleaning and maintenance
– Milk jug, milk tube and
connecting tube", until
water flows continuously
through the brew head.
The type of milk used is not
suitable for frothing.
Froth made from various
types of milks differs as does
the quality of the resulting
froth. Half-cream or full-
cream cow'smilk delivers
good results.
Milk is being sprayed
on to the table.
The connecting hose A15 is
not correctly installed.
Install the connecting tube
A15 correctly. Proceed
according to instructions
in section "Setting up the
system for automatic
frothing".
The descaling process
indicator is flashing
continuously even
after the descaling
process is finished.
The descaling process is not
yet finished.
Please be patient and wait
for the process to finish.
The appliance will turn off
automatically, please do
not turn off this appliance
manually.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Sencor SES 9200CH wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info