555888
4
Zoom out
Zoom in
Vorherige Seite
1/4
Nächste Seite
4/4 Operating Instructions CB1B1425en_01 / 2014-11-26 Siemens Building Technologies
Does symbol appear on the display?
Symbol
is displayed when the batteries are low.
Replace them with 2 new alkaline batteries type AAA.
Proceed as follows:
· Get 2 new alkaline batteries type AAA
· Remove the battery holder and then the batteries.
Insert the new batteries and, within 1.5 minutes,
replace the battery holder
· Ensure the exhausted batteries are disposed of
correctly, in compliance with environmental
requirements
Do you want to lock the keypad?
Mode Press and hold Mode for at least 7 seconds to
activate a button lock. Repeat to unlock.
The unit operates normally when the buttons
are locked, but changes cannot be made.
Receiver’s LED indication
State of receiver State of LED
Power up (or reset) The red and green LEDs flash
alternately for 5 seconds, then
change to constantly red.
Note: If the receiver was previ-
ously programmed, it shows
immediately constantly red.
Learning mode
Successful learning
mode
The red and green LEDs flash
alternatively.
If RCR100RF learning is
successful, the green LED will
flash for 10 minutes.
Signal ok and
output status
change
The green LED is constantly lit,
and if the output status
changes, the green LED flashes
for 3 seconds, then changes
back to constantly green.
Fail to receive
wireless data
If the RCR100RF fails to receive
wireless data, the red LED will
start to flash after 125 minutes.
If the RCR100RF signal is
recovered, it will return to the
previous LED state.
Do you want to change parameters?
+
Ok
Mode
If you want to change control parameters,
proceed as follows:
· Press + and simultaneously for 5
seconds
· Release the buttons and parameter
P01 is displayed on the bottom
segment
· Press + or to scroll to the parameter
that needs to be changed
· Press Ok to select the parameter
· Press + or to change the value
· Press Ok to confirm the changed value
· Press Mode to exit the parameters
without saving or wait for the program
to exit automatically
Parameter list
Parameter
no.
Description Setting range
(default)
P01 Time format 1 = 24:00 hours
(default)
2 = 12:00 am/pm
P02 Selection of °C or
°F
1 = °C (default)
2 = °F
P03 Standard
temperature display
1 = room temperature
(default)
2 = setpoint
P04 Temperature
sensor calibration
-3…3 °C
Step 0.5 °C
(-6…6 °F, step 1 °F)
Default: 0 °C
P06 Comfort setpoint
lock
0 = OFF (default)
1 = ON à locked
according to setting
in permanent
temperature setpoint
P08 Economy setpoint
lock
0 = OFF (default)
1 = ON à locked
according to setting
in permanent
temperature setpoint
P09 Buzzer 0 = OFF
1 = ON (default)
P10 Show frost
protection icon
0 = OFF (default)
1 = ON
P11 Time switch type for
Auto Timer
0 = individual days
(default)
1= all 7 days
2= 5-2 days
P12 Periodic pump run 0 = OFF (default)
1 = ON
P14 X1 external input 0 = no input (default)
1 = external sensor
2 = digital input
P15 Temperature
limitation
0 = OFF (default)
1 = ON
P16 Max. limitation
temperature for
floor heating
35…60 °C, step 1 °C
or
95…140 °F, step 1 °F
Default: 55 °C
P17 Window contact
features
0 = normally open
contact (default)
1 = normally closed
contact
P19 Sequential number
of room unit
0 = no display of
zone (RF off)
1 = zone number 1
(for standard RF)
(default)
6 = zone number 6
P20 RF learn 0 = OFF (default)
1 = ON
P21 Scanning rate for
the capacitive
buttons
Note: Shorter
scanning rate
means shorter
battery life
0.2 = 0.25 s
0.5 = 0.5 s
1.0 = 1.0 s (default)
1.5 = 1.5 s
P22 Reload factory
settings
0 = OFF (default)
1 = reload
P23 Software version
information
No adjustment
possible
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Siemens RDE100.1RFS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Siemens RDE100.1RFS

Siemens RDE100.1RFS Bedienungsanleitung - Deutsch - 3 seiten

Siemens RDE100.1RFS Bedienungsanleitung - Holländisch - 4 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info