Memory slot
Mem
Setting
range
Val
Description of respective
functions
Default setting = Val
marathon tiga SL(X)
021 0–40 Start of soft run ramp for gate/door end
OPEN position
Start of soft run ramp prior to drive mechanism moving into
gate/door end OPEN position. Adjustable in steps of
0.25 seconds.
15
022 15–60 Soft run speed when closing 25
023 15–60 Start of soft run ramp for gate/door end 45
4)
Note!
Memory position (023) can only be modified after the control system has been reset (force
values deleted). Such a system reset cannot be completed with the TorMinal software.
024 0–40 Start of soft run ramp for gate/door end
CLOSE position
Start of soft run ramp prior to drive mechanism moving into
gate/door end CLOSE position. Adjustable in steps of
0.25 seconds.
15
026 0–255 Cycle counter for maintenance
Indication of a set value which when reached should
activate the maintenance signal.
Example: input of a set value of 2 means that after
512 cycles the equipment should be serviced. If the next
service is required after a further 512 cycles, then a value
of 4 has to be input during the given maintenance session.
0
027 0–255 Early warning period OPEN
Duration of early warning period, adjustable in steps of
0.25 seconds. 4 = 1 second, 40 = 10 seconds
16
028 0–255 Early warning period CLOSE
Duration of early warning period, adjustable in steps of
0.25 seconds. 4 = 1 second, 40 = 10 seconds
20
030 1–20 Closing time with light barrier or extension
of gate open time
Depending on DIP switch positions 4 or 5, whereby DIP
switch 4 has precedence:
DIP 4 OFF: Standard gate open time
DIP 4 ON: Gate closes X seconds after the light
barrier has been triggered.
DIP 5 OFF: Standard gate open time
DIP 5 ON: After the light barrier has been triggered, the
gate open time is extended by X seconds
Adjustable in steps of 1 second.
5
Start of soft run ramp
Start from gate/
door end
OPEN position
Start of soft run ramp
Stop in gate/
door end
CLOSE position
Start from gate/
door end
CLOSE position
Stop in gate/
door end
OPEN position