Memory slot
Mem
Setting
range
Val
Description of respective
functions
Default setting = Val
marathon tiga SL(X)
031 2–255 Gate open time
Adjustable in steps of 1 second.
30
032 0–255 Clearing time
Adjustable in steps of 0.25 seconds.
40
033 0–255 Back jump
Adjustable in steps of 1 millisecond.
20
034 4–255 Reversing period
Duration of reversing period when safety input has been
tripped or when automatic power cut-off occurs.
Adjustable in steps of 0.25 seconds.
8
035 0–255 1. Switching soft run ramps ON or OFF
This function enables the soft run ramps to be switched ON
or OFF individually.
All soft run ramps (1–4) activated = 15
Ramp 1 (start from gate/door end CLOSE position) ON = 1
Ramp 2 (stop in gate/door end OPEN position) ON = 2
Ramp 3 (start from gate/door end OPEN position) ON = 4
Ramp 4 (stop in gate/door end CLOSE position) ON = 8
Setting and memorising required values
Example 1:
Switch off ramp 1 + ramp 2:
15 - 1 -2 = 12, input and memorise this value (12).
Example 2:
Switch on ramp 2 + ramp 4:
2 + 8 = 10, input and memorise this value (10).
3. Maintenance monitoring
Before the maintenance monitoring mode can be activated,
the number of cycles requiring monitoring needs to be set
on memory slot 026.
– monitoring function OFF = 0
– monitoring maintenance cycles = 64
– maintenance alarm has been activated = 128
When the maintenance alarm has been activated, the value
set on memory slot 035 is increased by 128.
Deleting maintenance alarm: reduce value set on memory
slot 035 by 128.
15
037 16–60 Force tolerance
Adjustable additional force tolerance
16 = min. additional force, 48 = max. additional force
48
4)
Note!
Memory position (037) can only be modified after the control system has been reset
(force values deleted). Such a system reset cannot be completed with the TorMinal software.
047 – For factory testing purposes –