Installation
14
Connection to power mains
Permitted cable cross-sections for main switch:
0.75 mm² - 10 mm².
Accessories: Internal push-button
Installation and connection
The standard equipment includes a push-button in the control
housing, which can be replaced at any time with another push-
button (1 or 3).
When pushing the button, the user should not stand in the
door's travel range and the user must have a clear view of the
door.
• Never lead the key switch cable along the power line, as this could cause
interference to the control system.
• Lay button cable and secure in position.
• Install push-button (1) in an appropriate, easily accessible location in
the garage. Minimum height from the floor: 1.6 m
• Install button cable (2) in garage. Connect end of cable to button (1).
Alternatively a pull-cord switch (3) can be installed.
Minimum height of the cable end from the ground: 1.6 m
Input Output Description
2T1 1L1 freely selectable
4T2 3L2 freely selectable
6T3 5L3 freely selectable
PE PE Earth conductor
The connection to the power supply must be carried out by a qualified
electrician.