Connections
24
Variant 1: Fraba system + photoelectric cell
Terminal 6 Cable green from the Fraba system via photoelectric
cell only if DIP switch 2 is ON
Terminal 10 regulated 24 V DC, max. 0.1 A
Terminal 11: Earth
Terminal 20 Cable brown from the Fraba system (DC 12 V)
Terminal 21 Cable white from Fraba system (Earth)
Settings: see section on “Obstruction in door travel path”
Connections for signal light
controller 1
• Permissible cable cross-section: 1 mm
2
... 2.5 mm
2
.
Connection strip for the signal lights (incl. mains supply) and potential-free
relay contact (e.g. garage lighting).
Terminal Designation/function
Mains supply
L (1) AC 220 ... 240 V
N (2) Neutral conductor
PE (3) Protective earth
Voltage tap mains power
PE (4) Protective earth
N (5) Neutral conductor
L (6) AC 220 ... 240 V
Signal light connections (max. 2 x 40 W each)
N (7) Neutral conductor GI
GI (8) Signal light green inside
N (9) Neutral conductor RI
RI (10) Signal light red inside
N (11) Neutral conductor RI
GA (12) Signal light green outside
N (13) Neutral conductor RA
RA (14) Signal light red outside
Potential-free relay contact
Light (15 + 16)
Connections for signal light
controller 2
• Permissible cable cross-section: 0.5 mm
2
... 2.5 mm
2
.
Connection strip for control cable that comes from the operator.
Terminal SIG 0 Terminal 17 on control unit
SIG 1 Terminal 19 on control unit
SIG 2 Terminal 24 on control unit
Terminal 23 on control unit
Connection to power main
Permitted cable cross-sections for main switch:
0.75 mm² - 10 mm².
Input Output Description
2T1 1L1 freely selectable
4T2 3L2 freely selectable
6T3 5L3 freely selectable
PE PE Earth conductor
The connection to the power supply must be carried out by a qualified
electrician.