26
The accessories depicted here are not included in the scope of
delivery. They must be ordered separately.
Other pulse generators include: Remote control transmitters,
Telecody, radio-operated interior switches and key-operated
buttons. No connection line to the operator needs to be installed
for the remote control transmitters, Telecody or radio-operated
interior switches, ask your dealer.
1. Red / green signal light
2. Key-activated button (1 contact or 2 contact)
3. Photoelectric cell
4. Junction box
5. Flagpole aerial (incl. 6 m, 10 m or 16 m cable)
6. Release lock
7. Pull-cord switch
8. Telecody
9. Slip-door safety mechanism
10. Safety contact strip: 8.2 k Ohm or Fraba
11. TorMinal
Additional accessories on request.
9. Slip-door safety mechanism
Attention!
Always connect the slip-door safety mechanism to safety input 2
(terminals 8 + 9). If the slip-door safety mechanism is connected
to the trolley, then the operator will not recognise the door posi-
tion.
Always connect the slip door switch as opener.
Terminals 8 + 9 Tested connection for potential-free contacts,
only reacts if door is open