Installation
9
Gate Wing Fittings
1. Close gate.
2. Mount hinge plate at the push rod of the drive.
Insert screws but do not tighten.
3. Clamp the hinge plate to the gate wing and complete a programming run
to ensure that the limit switch settings are correct.
4. At three different positions, inspect drive and ensure that it is in a hori-
zontal position:
A. Gate “CLOSE”
B. Gate “OPEN”
C. Gate at 45° angle
5. Check position of hinge plate; if ok, secure hinge plate to wing.
6. Tighten nut at screw, ensuring that the drive can still be easily moved.
Timber post fittings
Available as optional accessories.
Installation of Control Unit
The power cable supplied with the control unit may only be
used for the installation of the drive systems. After completion
of the installation, disconnect the cable and replace it with a
duct-laid cable. It is forbidden to use the supplied power cable
for standard operation of the gate.
Establish power connection according to EN 12453 (all-pole
disconnecting switch).
• Prior to carrying out any work at the control unit, disconnect it from the
power supply.
• If there is humidity inside the housing, dry it with a blower.
• The control unit may only be connected to the power supply by a
qualified electrician.
• Install control unit in upright position (cable ducts at base) and without
applying any strain. The cover must fully close to prevent water from
penetrating the housing.
• The cable ducts are designed for 1.5 mm² to 2.5 mm² cables.
Do not use any other cables.
• Attach the housing at the intended fixing points; do not drill through the
rear wall of the housing, as it might otherwise not be waterproof.