GB 36
At continuous operation of the H2O fireplace insert low flue gas tem-
peratures can result in chimney damage if the chimney systems are
not suitable. For this reason, we recommend that an hourly wood feed
quantity of 5-6 kg during a burn day not be underranged.
The thermally activated flue gas damper integrated in the heat exchanger of
the the H2O fireplace insert Mini Z1 H2O-series, Nova E H2O, Varia Ah H2O and
Varia AFDh H2O automatically controls the function. At a sufficiently high flue
gas temperature (approx. 150°C), the flue gas damper closes automatically.
Thus the flow of flue gas is diverted through the heat exchanger. If the flue gas
temperature drops under this temperature again, the flue gas damper opens.
For better efficacy of the heat exchanger, the H2O fireplace insert should be fired
as uniformly as possible, and frequent burn-down to the basic embers should
be avoided in order to obtain heat dissipation of the heat exchanger that is as
uniform as possible and to avoid low chimney temperatures.
Double glazing (IR reflective surface): Through application of oxidic coat-
ings on the glass surface, infrared spectral components from the com-
bustion chamber are reflected to a great extent. These coatings generate
the interference colours (similar to a rainbow), the so-called IR reflective
surface. Through this colouration, the quality characteristic of the "IR
reflective surface" is visible, i.e. recognisable. This colouration cannot
be removed.
To operate the fireplace insert with nominal heat output, the following
prerequisites are necessary.
The fireplace insert must be heated up (wood has already been supplied
2-3 times).
Combustion must be operated with a closed door.
Chimney draught: 12-14 Pa
Wood: Dry beech wood; (moisture < 18%)
Wood feed quantity: „1.3 Technical data“
Air setting: Approximately middle position, may need to be slightly
adapted depending on local conditions (see example). During the com-
bustion phase the air lever can be opened for several minutes.
instructions concerning the general operation of the H2O fireplace insert
are provided in the operating instructions for Spartherm fireplace inserts.
The H2O fireplace inserts/heating systems must be filled and vented before
firing. In this process the heating system pressure must be checked (~1.5
bar). After commissioning venting must be executed daily. As soon as cold
air no longer accumulates the interval can be extended.
The heating system and the stove/fireplace insert must be filled with water
treated in accordance with VDI 2035 Sheet 1.
4. OPERATION
For operation, also comply with the operating instructions in the manual
for our fireplace inserts. The information in these installation and operating
instructions refers to special operation of a fireplace insert with integrated
water heat exchanger.
The combustion chamber door must be self-closing for multiple-con-
nection flue gas systems. The door may only be opened to put on more
firewood or for cleaning when in a cool state. Manipulation of the
closing device is prohibited. If a single-connection system is present,
the combustion chamber door must not be self-closing! However the
combustion chamber doors must always be closed during combustion!
IMPORTANT: The provided heat-resistant glove serves only as ther-
mal protection when activating the operating handle and the cold
hand. The glove is not fire-proof.
The distance between flammable parts/furniture and the view pane must
be at least 80 cm!
The fireplace insert is designed for the burning of dry, untreated wood
logs with adhering bark and wood briquettes. Do not use other fuels.
Operation in the partial load range results in low flue gas temperatures.
36

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Spartherm Mini H2O wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Spartherm Mini H2O

Spartherm Mini H2O Bedienungsanleitung - Deutsch - 44 seiten

Spartherm Mini H2O Bedienungsanleitung - Holländisch - 44 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info