controller is approximately 500 W at alternating current AC 230.
The factory settings of the thermostat have been pre-set to approximately
62°C. With this pre-set, the switch-on temperature and switch-off
temperature of the circulation pump of the return flow boost are defined
when the necessary water temperature in the water heat exchanger
is reached or undershot. Optionally, if the conditions so require, the
temperature can be adjusted by the installation company. For this, depend-
ing on the version of the thermostat, the rotary adjuster is adjusted, or the
cover (D=10 mm) is taken off. After removing the cover, the temperature
range can be changed. The pump thermostat must not be housed in the hot
area of the heating chamber (convection chamber) of the fireplace system
(max. ambient temperature 80°C). Select the position in accordance with
the capillary tube length in the cold area!
Please note: At water temperatures below 60°C the danger of undershooting
the dew point increases! This can cause gloss soot. In addition, the clean-
ing interval is shortened. Consequently, we recommend that the switch-on
temperature is not to be set below 60°C and not above 68°C. For some
heating systems, it can be necessary to install a flue gas thermostat in
addition to the pump thermostat. This prevents the buffer tank from cool-
ing above the tiled stove insert. Ask the installation company if there are
questions in this regard
2.10 INTEGRATION IN A HEATING SYSTEM
Please note: The Nova E H2O must only be installed in an overall system
after detailed planning of the overall heating system in accordance with the
relevant rules of technology and the safety standards. The proper configura-
tion of the pumps, fittings, pipeline, buffer tank and the safety components,
such as safety valve and expansion tank, is the responsibility of the planning
firm and/or of the executing installation company. Bear in mind that during
the combustion phase, extremely high water throughput of approx. 25 kW
can briefly occur. The heating installations must be configured accordingly,
among other things.
The following sample calculation can be helpful for dimensioning the buffer
tank:
The following assumptions have been made in this regard:
PSize of the buffer tank: 500 l (approx. 500 kg water)
Water temperature in the buffer tank at the beginning: 30 °C
Water temperature in the buffer tank at the end: 60 °C
Temperature differential 30 °C (corresponds to 30 K))
No heat withdrawal from the buffer tank during warm-up by the Nova E
H2O and no heat losses from the syste
This means: To heat up 500 litres of water in a buffer tank, from an assumed
30°C to 60°C a theoretical heat quantity of 62805 kJ (= 62805 kWs) is
required (losses or heat withdrawals in the system have not been taken into
account). This heat quantity corresponds to approx. 17.5 kWh. However,
with an effective setup of the heating system, e.g. of a stratified storage
tank, the heat utilisation can begin shortly after start of circulation in the
Nova E H2O. In this case, only the excess energy will be stored in the buffer
tank, not the energy required for heating.
At an average assumed power of approx. 9 kW of the Nova E H2O, heat-up
of the entire buffer tank takes just under 2 hours.
On extremely cold winter days, it is possible that the fireplace system may
also be in operation for approximately 12 hours. In this case, the thermal
energy thus produced is theoretically 93 kWh. This thermal energy would
then be sufficient to heat just under 2,666 litres of water (from 30°C to
60°C). As a rule, in such a situation heat is also continuously withdrawn so
that overloading of the buffer tank (> 90°C) should not occur.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Spartherm Nova E H2O wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Spartherm Nova E H2O

Spartherm Nova E H2O Bedienungsanleitung - Deutsch - 28 seiten

Spartherm Nova E H2O Bedienungsanleitung - Holländisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info