8 9
USB Po wer Port will not power appliance
LED Area Light does not come on
Portable Compressor will not inflat e
securely inserted into connector (chuck) on all other infla tables.
AC CESSORIES
Recommended accessories for use with y our tool are av ailable from the manufacturer . If you need assistance r egarding accessories ,
please contact the manufacturer at (877) 571-2391.
WARNING: The use of an y accessor y not rec ommended for use with this appliance could be hazardous.
SERVICE INFORMA TION
Whether you need t echnical advice, repair , or genuine fac tory replacement parts, contact the manufacturer at (877) 571-2391.
ONEYEAR LIMITED W ARRANT Y
The manufacturer warr ants this product against defec ts in mat erials and workmanship for a period of ONE (1) YEAR from the dat e
If there is a defect and a valid claim is r eceived within the W arranty Period, the defective pr oduc t can be r eplaced or repaired in the
following wa ys: (1) Return the product to the manufac tur er for repair or replacemen t at manufacturer ’ s option. Pr oof of purchase
that the stor e is a par ticipating r etailer). Returns to retailer should be made within the time period of the retailer’ s return policy
This warr anty does not apply to accessories, bulbs, fuses and ba tteries; defects resulting from normal wear and t ear , accidents;
damages sustained during shipping; alterations; unauthoriz ed use or repair; neglect, misuse, abuse; and failur e to follow
instructions for care and maintenance for the pr oduct.
This warr anty gives you, the original retail pur chaser , specific legal rights and you ma y have other rights which vary from stat e to
state or pr ovince to pro vince. This product is not intended for commer cial use.
Please complete the Pr oduc t Registra tion Card and return within 30 da ys from purchase of the pr oduc t to: Baccus Global LL C, 595 S.
Feder al Highway , Suite 210, Boca Raton, FL 33432.
SPECIFICA TIONS
instantaneous
, 5 seconds 300A
Battery T ype: Maintenance-free , sealed lead acid, 12 volt DC, 19aH
Area Light: 1 long-life white LED
Imported by
Baccus Global LL C
595 S. Feder al Highway , Suite 210
Boca Raton, FL 33432
(877) 571-2391
RD031113
4. T urn on the Compressor P ower S witch.
5. Check pr essure with the pressur e gauge.
6. When desired pr essure is reached , open thumb latch and remov e the SureFit™ nozzle connector fr om the valve stem.
7. T urn off Compressor P ower S witch.
8. Allo w unit to cool before storing a way .
9. St ore compressor hose and tir e fitting in storage compartment.
Inflating Other Inflatables Without Valve Stems
Inflation of other items r equires use of one of the adapters (nozzles).
1. Select the appropriat e adapter nozzle.
2. Lift the thumb lat ch on the SureFit™ nozzle, insert the adapter (i.e. needle) int o the SureFit™ nozzle connector and close
thumb latch.
3. Insert adapter (i.e., needle) int o item to be inflated .
IMPORT ANT NOTE: Small items such as volleyballs , footballs, etc. inflat e ver y rapidly . D o not ov er-inflate.
5. Remov e adapter .
6. S witch the Compressor P ower S witch off .
7. Allo w unit to cool before storing a way .
8. St ore compressor hose and tir e fitting in storage compartment.
WARNING: TO REDUCE THE RISK OF INJURY OR PROPERT Y D AMAGE: FOLLOW ALL SAFET Y INSTRUCTIONS FOUND IN
CARE AND MAINTENANCE
All batteries lose ener gy from self-discharge over time and mor e rapidly at higher tempera tures. When the unit is not in use, w e
recommend tha t the batter y is char ged at least every 30 days.
Never submer ge the unit in water . If the unit gets dir ty , gently clean the outer surfaces of the unit with a soft cloth moistened with a mild
solution of wat er and detergent.
Ther e are no user-replaceable parts. P eriodically inspec t the condition of adapters , connectors and wires. C ontact manufac turer t o
replace an y components that hav e become worn or brok en.
Battery replacement/disposal
BA T TER Y REPLACEMENT
The batt er y should last the ser vice life of the unit . Contact manufacturer for any information y ou may need.
SAFE BA TTERY DISPOSAL
Contains a main tenance-free, sealed, non-spillable , lead acid batter y , which must be disposed of properly . Rec ycling is
requir ed, contact your local authority for information. F ailure to c omply with l oc al , sta te a nd fe de ra l reg ul ati on s ca n
result in fines , or imprisonment.
Contact your local w aste management authority to dispose of this product.
PLEASE
RECYCLE
WARNINGS:
in injur y or fir e).
12 volt DC charger plug fuse replacement (optional accessory)
The fuse in the plug end of the 12 v olt DC charger protects the adapter’ s charging circuit. If the 120 v olt AC charger oper ates, but the DC
charging adapter does not , then this fuse may be opened (blown).
T o replace the fuse:
1. Unscrew the end cap of the DC plug (c ounterclockwise).
2. Remove spring c enter contact and fuse.
3. Check fuse with a continuity checker .
4. If blown, locate a r eplacement 8 amp volt fuse.
5. Replace the fuse, spring , contact and end cap.
TROUBLESHOOTING
Unit will not charge