- 16 -
- 17 -
In order to exclude additio-
nal areas such as paths or
neighbouring property or to
monitor these specifically,
the detection zone can be
adjusted precisely by
means of shrouds.
The shrouds can be sepa-
rated along the pre-grooved
divisions in the vertical or
horizontal direction or cut
with scissors.
The shrouds can then be
suspended in the upper
notch in the middle of the
lens and finally fixed in
place by applying the
decorative cover.
(Refer below: examples
concerning reduction of
angle of coverage and
reduction of reach.)
Individual fine adjustment with shrouds
Examples
Examples
Reach – basic settings
The sensor halogen light
lens is divided into two
detection zones. With one
half, a max. reach of 5 m is
achieved and with the other
a max. reach of 12 m (for
an installation height of
approx. 2m). After the lens
has been applied, a small
arrow marks the selected
max. reach of 12 m or 5 m.
(Arrow to left = 5 metres,
arrow to right = 12 metres).
The lens can be released
laterally from the catch with
a screwdriver and rein -
serted according to the
desired reach.
Twilight setting
(response threshold)
The desired sensor
response threshold can be
ad justed continuously from
approx. 2 lux to 2000 lux.
When the adjustment screw
is at the left stop position,
this means twilight opera -
tion of approx. 2000 lux.
When the adjustment screw
is at the right stop position,
this means twilight oper -
ation of approx. 2 lux. The
adjustment screw must be
at the left stop position
when setting the detection
zone and for the functional
test in daylight.
2-2000 Lux
GB