– 14 – – 15 –
Mounting
• Mark drill holes (Fig. 4.4)
• Drill holes and insert wall plugs - concealed
power supply cable (Fig. 4.5)
• Connect conductors (Fig. 4.6)
• Fit house number panel (L 630) to the light
enclosure (Fig. 4.7)
• Connect plug-in terminal, wall mount and light
enclosure (Fig. 4.8)
• Install light enclosure on wall mount (Fig. 4.9)
• Screw in retaining screws (Fig. 4.9)
• Switch ON power supply (Fig. 4.10)
• Make settings (Fig. 5.1)
➔ "5. F unctions"
5. Functions
Once installed, the sensor-switched light can be
put into oper ation. Control dials are provided on
the sensor unit for selecting the time-, twilight- and
progr amme settings.
F actory settings:
Pr ogramme setting: P1
T wilight level: 2000 lux
Time setting (switch-OFF delay: 5s)
• Remove the sensor after pressing the locking tab
with a flat-tip screwdriver (Fig. 5.1)
– The sensor-switched light switches t o manual
override (permanently ON)
Progr amme setting (5.1 F)
P1 Standard progr amme
– Soft light start / no basic light level
What is soft light start?
The sensor-switched light featur es a soft light start
function. This means that when turned ON, the
light is not switched directly to maximum output
but constantly builds up brightness to 100 % within
a short period of time. Brightness is also gradually
reduced when the light is switched OFF .
P2 User-friendly pr ogramme
– Soft light start + basic light level
– Basic light level ON from twilight setting selected.
What is basic light level?
The basic light level provides continuous night-
time illumination at approx. 10 % light output. The
light only switches to maximum output (100 %) for
the time selected in response t o movement in the
detection zone. The light then returns t o the basic
light level (approx. 10 %).
Note: Depending on the local power grid, the LEDs
may flicker slightly when dimmed. This is not a
product defect and no reason for complaint.
Р 3 Comfort economy programme
– Soft light start + basic light level until the middle
of the night
– Basic light level ON from twilight setting selected
until the middle of the night
What is the comfort economy programme?
The sensor-switched light does not have an int egrat-
ed clock. The middle of the night is only determined
on the basis of the length of darkness phases.
T o work perfectly, therefore, it is important for the
sensor-switched light t o be permanently connected
to the power supply during this period. During the
first night (calibration phase) basic light level r emains
activated throughout the night. The values ar e saved
even in the event of a mains power failure. W e do
not recommend interrupting the power supply during
the progr amme. As the values are determined over
several nights, the sensor -switched light should, in
the event of any fault occurring, be monitored over
several nights t o ascertain whether the switch-o
time moves towards midnight.
Р 4 Nightmatic programme
– Soft light start, no basic light level, no movement
evaluation
– Switches on at 100 % if the light level falls below
the level set
T wilight setting (5.1 G)
The chosen response threshold can be infinit ely
varied from appro x. 2 - 2000 lux.
– Control dial set to = daylight oper ation
(independent of ambient brightness)
– Control dial set to = night-time oper ation
(approx. 2 lux)
T o adjust the detection zone in daylight operation,
the control dial must be set to (daylight
operation).
Time setting (5.1 H)
The light's ON time can be set to any period from
approx. 5s t o a maximum of 15min. Any move-
ment detected befor e this time elapses will restart
the timer .
Manual override function (Fig. 5.2)
If a mains switch is installed in the mains supply
lead, the following functions are available in addi-
tion to simply switching light ON and OFF:
8� Disposal
Electrical and electronic equipment, accessories
and packaging must be recycled in an envir onmen-
tally compatible manner .
Do not dispose of electrical and electronic
equipment as domestic waste.
EU countries only:
Under the current Eur opean Directive on W aste
Electrical and Electronic Equipment and its imple-
mentation in national law , electrical and electronic
equipment no longer suitable for use must be coll-
ected separately and recycled in an envir onmentally
compatible manner .
9. Manufacturer's warranty
This STEINEL pr oduct has been manufactured with
the utmost care, test ed for proper operation and
safety and then subjected to r andom sample in-
spection. Steinel guar antees that it is in perfect
condition and proper working order . The warranty
period is 36 months and starts on the date of sale
to the consumer . We will remedy defects caused
by material flaws or manufacturing faults. The war -
ranty will be met by r epair or replacement of de-
fective parts at our own discretion. The warr anty
shall not cover damage to wear parts, damage or
defects caused by improper treatment or maint e-
nance. F urther consequential damage to other
objects shall be excluded.
Claims under the warranty will only be accept ed
if the unit is sent fully assembled and well-packed
with a brief description of the fault, a receipt or in-
voice (date of purchase and dealer's stamp) t o the
appropriate Service Centre.
Repair service:
If defects occur outside the warranty period or ar e
not covered by the warr anty, ask your nearest ser-
vice station for the possibility of repair .
MANUFACTURER'S
1
3
5
YEAR
GB
WARRANTY
MANUFACTURER'S
WARRANTY
MANUFACTURER'S
YEAR
WARRANTY
Sensor operation
1) Switch light ON (when light is OFF):
Switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Switch OFF and ON once.
Light goes out or switches to sensor oper ation.
Manual override
1) Activate manual override:
Switch OFF and ON twice. The light is set to stay
ON for 4 hours (red LED lights up behind the lens).
Then it returns automatically t o sensor operation
(red LED o ).
2) Deactivate manual override:
Switch OFF and ON once. Light goes out or
switches to sensor oper ation.
Important:
The switch should be actuated in r apid succession
(in the 0.5 - 1s range).
Adjusting the detection zone (Fig. 5.3 to 5.8)
The detection zone can be limited t o suit require-
ments. The shrouds supplied with the unit can be
used to mask out as many lens segments as you
wish. This prevents the light from being activat ed
unintentionally, e.g. by cars, passersby etc., and
allows you to target danger spots. The shr ouds can
be cut along the grooved vertical divisions. Then
you simply clip them onto the lens.
6. Other information
Example providing help on applying the house
number using the sheet of house numbers
included. (Fig. 6.1)
7. Operation / maintenance
The sensor-switched light is suitable for switching
light ON and OFF automatically . We at her c on dit io ns
may aect the way the sensor-switched light func-
ti on s. Strong gusts of wind, snow , rain or hail may
cause the light to come ON when it is not wanted
because the sensor is unable to distinguish sudden
changes of temper ature from sources of heat. The
detector lens may be cleaned with a damp cloth if
it gets dirty (do not use cleaning agents).
GB