650320
14
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
14 | DHB-E AU www.stiebel-eltron.com
INSTALLATION
Troubleshooting
13. Troubleshooting
WARNING Electrocution
In order to check the appliance it must be connected to
the power supply.
13.1 Indicator options for LED diagnostic traffic light
Indicator options
Red Illuminates in the event of a fault
Yellow Illuminates during heating mode
Green Flashing: Appliance is supplied with mains power
13.2 Fault table
Fault / diagnostic traffic light LED
display
Cause Remedy
The appliance does not start. The shower head / aerators are scaled up. Descale or if necessary replace the shower head / aera-
tors.
Inadequate flow rate. The strainer in the appliance is dirty. Clean the strainer.
The set temperature is not achieved. One phase down. Check the fuses/MCBs in your fuse box/distribution panel.
The heater switches off. The air sensor detects the presence of air in the water
and briefly interrupts the heating output.
The appliance restarts after one minute.
No hot water and no traffic light display.
The MCB/fuse has responded/blown. Check the fuses/MCBs in your fuse box/distribution panel.
Safety pressure limiter AP 3 has tripped.
Remove the cause of the fault (e.g. faulty pressure wash-
er).
Protect the heating system against overheating by open-
ing a draw-off valve downstream from the appliance for
one minute. This depressurises and cools down the heat-
ing system.
Activate the safety pressure limiter at flow pressure by
pressing the reset button; see also chapter "Commission-
ing/ Initial start-up".
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: Green flashing
No hot water at flow rate >3l/min.
Flow sensor DFE is not plugged in. Plug the flow sensor plug back in.
Flow sensor DFE is faulty. Check the flow sensor and replace if necessary.
The set temperature is not achieved.
The set value transducer or connecting cable is faulty, or
the connecting cable is not attached.
Attach the connecting cable; replace the set value trans-
ducer if required.
Temperature limiting is activated. Disable temperature limiting.
Traffic light display: Yellow constantly on;
green flashing
No hot water at flow rate >3l/min.
The high limit safety cut-out has responded or its lead
is broken.
Check the high limit safety cut-out and replace if neces-
sary.
The heating system is faulty. Measure the resistance of the heater and replace if nec-
essary.
The PCB is faulty. Check the PCB and replace if necessary.
Traffic light display: yellow constantly on;
green flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor if
necessary.
Set temperature is not achieved. Appliance is operating at its output limit. Reduce the flow rate or install the flow limiter.
Traffic light display: red constantly on; green
flashing
The outlet sensor is faulty. Check the connection and replace the outlet sensor if
necessary.
No hot water
The cold water sensor is faulty. Check the PCB and replace if necessary.
Required temperature >45°C not achieved The cold water inlet temperature exceeds 45°C. Reduce the cold water inlet temperature to the appliance.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stiebel Eltron DHB-E 18 AU wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info