GENERAL CLEANING
Clean and inspect the appliance regularly, especially in periods of
heavy use. Regular cleaning and maintenance will help give many
years of safe use.
Allow appliance to cool thoroughly to avoid risk of burns.
Clean regularly, according to level of use.
Remove the ash completely.
Check internal components for damage - grates, bricks, baffles
- and for obvious build up of soot, ash or debris above the flue
baffle(s) (these can be found in the upper part of the firebox). Use
a torch if necessary.
If there are any signs of a build up of debris above the flue baffle(s)
either:
Arrange for the chimney to be swept.
Remove the baffles and clear the debris.
To refresh painted nishes a touch up spray is available.
Contact your Stovax retailer quoting the serial number found on
the appliance data badge.
Do not use aerosol sprays near an operating appliance.
CLEANING GLASS
Keep the glass clean with correct use of the Airwash system and
good quality fuel.
Sometimes additional cleaning may be required.
Before undertaking this operation allow appliance to cool fully. Do
not clean hot glass.
On appliances with printed glass do not use cleaning
agents that have a high alkaline or acidic content, these are
aggressive cleaning agents designed to be used with heavily
stained clear glass. On printed glass surfaces, use Stovax
Glass Cleaner (Stovax No.4103) which is better formulated for
this application.
Before applying a cleaning agent remove any dust and loose soot
with a damp cloth.
Use an appropriate glass cleaner. Apply the cleaning fluid to a
cloth before rubbing onto the glass.
Apply carefully and do not apply excessively. Try to prevent any
run off which could soak into the rope seals around the edge of the
glass.
Soot can also contain acidic particles that can cause corrosive
damage to printed glass.
Remove dirt with a moist cloth and buff dry.
Some types of wood can cause a white residue to form on the
glass.
If this occurs it should be cleaned off at least once a week
during periods of heavy usage.
If the liquid cleaning agents recommended do not remove
this residue Stovax offer a dry cleaning pad which will help
remove heavy stains.
Before relighting the appliance ensure the glass is fully dried.
GB
If the rope seal has absorbed excess cleaning agent it is advisable
to replace the rope as soon as possible to preserve the printed
finish of the glass.
CHIMNEY SWEEPING
To maintain safe and efficient use of the appliance, the chimney/
flue must be inspected and swept at least once a year by a
qualified chimney sweep.
If the appliance is used continuously throughout the year, or it is
used to burn wood, more frequent sweeping is recommended.
The best time to have the chimney swept is at the start of the
heating season.
The chimney, any connecting flue pipe and the appliance flue
ways, if incorporated, must be regularly cleaned.
Ensure adequate access for cleaning where it is not possible to
sweep through the chimney.
If the chimney is believed to have previously served an open fire
it must be swept a second time within a month of regular use after
installation.
CO ALARMS
Building regulations require that whenever a new or replacement
fixed solid fuel or wood/biomass appliance is installed in a dwelling
a carbon monoxide alarm, complying with BS EN50291, must be
fitted in the same room as the appliance.
HETAS recommend the unit is permanently fixed in accordance
with the manufacturer's installation instructions or with the guidance
contained in Approved Document J where no other information is
available.
Provision of an alarm must not be considered a substitute for either
installing the appliance correctly or ensuring regular servicing and
maintenance of the appliance and chimney system.
SEASONAL USE
Clean and service the appliance if not used during the warmer
months, as detailed in the Maintenance and Servicing section.
Set the air controls to 50% to keep the appliance ventilated and
stop the build-up of any moisture inside.
Before re-lighting the appliance:
— Remove the baffles.
— Clear any debris that may have accumulated.
— Check the flue is clear of any blockages.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Stovax Studio wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Stovax Studio

Stovax Studio Installationsanweisung - Englisch, Französisch, Italienisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info