www.sunred.nl
OPERATION AND STORAGE
TO TURN ON THE HEATER
1. Turn on the valve on the gas supply cylinder completely.
2. Press and turn the variable control knob to PILOT position (counter-clockwise 90º).
3. Press down the variable control knob and hold for 30 seconds. While holding down the variable control knob, press
the igniter button several times until the pilot flame lights. Release the variable control knob after the pilot flame
lights.
Note:
- If a new tank has just been connected, please allow at least one minute for the air in the gas pipeline to purge
out through the pilot hole.
- When lighting the pilot flame make sure that the variable control knob is continuously pressed down while
pressing the igniter button. Variable control knob can be released after the pilot flame lights.
- If the pilot flame does not light or it goes out, repeat step 3.
4. After the pilot flame lights, turn the variable control knob to maximum position and leave it there for 5 minutes or more
before turning the knob to desired temperature position.
Warning:check that the glass is not damaged before operation.
TO TURN OFF THE HEATER
1. Turn the variable control knob to PILOT position.
2. Press and turn the variable control knob to OFF position.
3. Turn off the valve on the gas supply cylinder completely.
Off: the heater stop work
Hi: maximum temperature position
Lo: minimum temperature position