664820
19
Zoom out
Zoom in
Vorherige Seite
1/192
Nächste Seite
19
If you press the [POWER] switch before the time has expired, the time programming is deleted, the
ENERGIC unit switches on and can be operated in the required operating mode.
Residual time: This function is used to automatically deactivate the ENERGIC unit when the time entered
has expired. Proceed as follows:
a) Press the [TIMER] switch during operation and enter the required number of hours after which the
ENERGIC unit is to switch off.
b) After the flashing of the number of hours on the LED has stopped, you can select the required function
(cooling, heating, dehumification) and the required temperature.
c) When the set number of hours has expired, the ENERGIC unit switches on automatically.
If you press the [POWER] switch before the time has expired, the Timer programming is deleted and the
ENERGIC unit switches off.
8. [SLEEP]
Using this key you can set the sleep function of the ENERGIC unit. The microprocessor integrated in the
ENERGIC unit will raise the pre-set temperature by 2°C per hour up to a maximum of 4°C after 2 hours
and maintain this temperature until the set time has expired.
If you use the sleep function, first set the time switch to the set hours as described in the functions
Residual time or Starting time. Then press the [TIMER] switch until the required hours appear on the
display. After the hour display, the display switches automatically to the previous set temperature display.
To change the temperature, press the switch [TEMP+] or [TEMP-]. With each press on the switch, the
temperature increases or decreases by 1°C.
COOLING
We recommend starting ENERGIC early in the morning on warm days to get a cool room.
This ENERGIC unit has a self-evaporation function for condensation water, so that it is normally not
necessary to empty the water tank in cooling mode. The drainage hose need not be connected.
Please make sure that the outlet is closed with the rubber cap during operation.
(This does not apply in the case of high air humidity. If the ENERGIC unit operates in cooling mode for a longer
period and especially at a time of year with high air humidity, the condensation tank may be full. The control lamp
will remind you to empty the water. Refer to error message E4. In such a case, empty the water tank via the
condensation water outlet. If continuous high air humidity is likely, it is recommended to drain the condensation
continuously via the drainage hose.)
COOLING IN INDOOR OPERATION
The ENERGIC unit stands in the room to be cooled.
Connect the air hose and the air outlet grid to the ENERGIC unit as displayed in the illustration; the air
hose connection piece and air outlet grid need to be exchanged.
The warm extract air must be emitted from the room via the air hose. This can be executed e.g. via a tilted
window, a door or wall aperture. Make sure that no warm outside air can enter the room. For effective
cooling, we recommend our selection of various accessories which reduce or prevent entry of warm air
into the room.
Set the function to „COOLING“. Set the target temperature using the temperature control. The settable
temperature range is between 17°C and 30°C target temperature. The ENERGIC unit must only be used
in an ambient temperature of maximum 35°C.
Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has
flashed for 3 minutes. Cooling effect may require a further 10 minutes. Further information is available under the item,
„Troubleshooting“.
COOLING IN OUTDOOR OPERATION
The ENERGIC unit is outside the room to be cooled.
Connect the air hose and the air outlet grid to the ENERGIC unit as displayed in the illustration; the air
hose connection piece and air outlet grid need to be exchanged.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Suntec Klimatronic ENERGIC plus 9.0 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info