GAIA – Wireless weather station
GAIA – Wireless weather station
5. Positioning of display unit and transmitter
With the foldable leg at the back of the unit, the base station can
be placed onto any flat surface or wall mounted at the desired
location by the hanging hole at the back of the unit. Avoid the
vicinity of any interfering field like computer monitors or TV sets
and solid metal objects.
Choose a shady and dry position for the transmitter. (Direct sun-
shine falsifies the measurement and continuous humidity strains
the electronic components needlessly)
Check the transmission signal from the transmitter to the display
unit (transmission range 100 m free field). Within ferro-concrete
rooms (basements, superstructures), the received signal is naturally
weakened.
If necessary choose another position for transmitter and/or
display unit.
To wall mount the transmitter, use 3 screws to affix the wall bracket
to the desired wall, plug in the remote sensor to the bracket (D2).
6. Battery replacement
If battery change happened on remote sensor side, then the base
station must be power up again to re-learn the transmitter.
Use alkaline batteries only. Observe correct polarity. Low batteries
should be changed soon to avoid the damage resulting from a
leaking battery. Batteries contain harmful acids. Wear protective
glasses and gloves when handling with leaked batteries.
Attention:
Please do not dispose of old electronic devices and used batteries
in household waste. To protect the environment, take them to
your retail store or to appropriate collection sites according to
national or local regulations.
7. Specifications
Transmission distance in open field: 100meter max.
Frequency: 433 MHz
Measuring interval sensor: 48 sec
Alarm duration: 120 sec
Temperature
Measuring unit: °C/°F
Measuring range outdoor: -40°..+65°C/-40°..+149°F
(shows OFL if outside range)
Measuring range indoor: 0°… +60°C / +32°…+140°F
(shows OFL if outside range)
Humidity
Measuring unit: %RH
Measuring range outdoor: 20% …95%
Measuring range indoor: 1% …99%
Resolution: 1%
Accuracy: ±5% @ 0...45°C
Atmospheric pressure
Measuring unit: hPa / inHg
Measuring range: 919 hPa – 1080 hPa
Resolution: 0.1 hPa
Accuracy: ±1.5 hPa
Batteries (not included)
Base station: 3 x AA 1.5V LR6 Alkaline
Remote sensor: 2 x AAA 1.5V LR6 Alkaline
8. Maintenance
Keep your weather station in a dry place.
Do not expose the instrument to extreme temperatures, vibration
or shock.
Clean it with a soft, damp cloth. Do not use solvents or scouring
agents.
Avoid placing the clock near interference sources/metal frames
such as computer or TV sets.
Please reset the unit and follow the battery installation procedure
if the unit does not work properly. Change the batteries.
9. Liability disclaimer
The product is not a toy. Keep it out of reach of children.
The product is not to be used for medical purpose or for public
information, but is determined for home use only.
The specifications of this product may change without prior notice.
No part of this manual may be reproduced without written con-
sent of TFA Dostmann.
Improper use or unauthorized opening of housing will mean the
loss of warranty.
Herewith we declare, that this wireless transmission
device does comply with the essentials requirements of
R&TTE Directive 1999/5/EC.
TFA Dostmann GmbH & Co. KG, D-97877 Wertheim
www.tfa-dostmann.de
TFA_No_35.1083_Anleitung 08.09.2008 12:14 Uhr Seite 11 (Schwarz/Process Black Auszug)
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

tfa-35.1083---gaia-funk

Suche zurücksetzen

  • Die Wetterstation bekommt keine Temperaturdaten vom Sender. Batterien sind neu eingesetzt was ist zu tun? Eingereicht am 29-12-2019 11:41

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für TFA 35.1083 - Gaia Funk wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info