TROUBLESHOOTING
Although rare, you may see an error or warning message display on your control panel. Please refer to the following chart for
potential issues and how to resolve them:
ERROR MESSAGE SOLUTION
High Temp Error This error will occur when the temperature in the grill reaches temperatures above
550°F (288°C) for more than 45 seconds. Let the grill cool, then turn o the grill. Clear
out any remaining pellets from the firepot and restart your grill. If the problem persists,
call customer service.
Low Temp Error This error will occur if the temperature of the grill falls below 120°F (49°C) for
10 minutes, causing the grill to go into shutdown mode. To fix, remove any pellets
from the firepot and add more pellets to the hopper. Turn the controller o and then
on again and restart your grill. If the problem persists, call customer service.
Temp Sensor Out This error will occur if the temperature of the grill is 695°F (368°C) or above for 10
seconds. This could be an adverse event. Allow the grill to cool down and restart the
grill. If the problem persists, call customer service.
Failed to Ignite This error will occur if the grill is out of pellets or the igniter did not light. Check to see
if there are pellets in the hopper and clean out your firepot. If the problem persists,
replace your igniter or call customer service.
Igniter Disconnect This error occurs when the controller does not detect the igniter. Check to see if the
igniter is connected and restart your grill. If the problem persists, replace your igniter
or call customer service.
Fan Disconnected This error occurs if the controller does not detect the fan. Make sure the fan is plugged
in and restart your grill. If the problem persists, you may need to replace your fan or
call customer service.
Auger Disconnected This error occurs when the controller does not detect the auger motor. Check to see
if the motor is plugged in and restart your grill. If the issue persists, replace your auger
motor or call customer service.
Auger Overcurrent This error occurs if the auger motor is damaged or jammed. Use the Clear Auger
feature inside the control menu and restart your grill. If the problem continues, you
may need to replace your auger motor or call customer service.
Low Temp Warning This warning will occur if the grill has lost its fire and failed to recover. Check the
pellets and restart the grill.
Ignition Warning (App
Notification Only) This warning will occur if the grill has not detected a successful ignition in the expected
time. Check the pellets and restart the grill.
Low Ambient Temp This warning will occur when the ambient temperature falls below -20°F (-29°C)
for more than 30 seconds. Although the controller will still work, damage to the
controllers display may have occurred. If the grill ignites, check to see if the display
operates as expected. If the grill does not ignite, warm the grill and check to see if the
display and controller operate as expected. If not, call customer service.
Probe Fell Out This warning will occur if the probe is not fully inserted into the food. The message is
triggered when the probe is above 220°F (104°C) while the grill is running. Reinsert the
probe into your food as instructed on pages 15 and 16.
Bad Probe This warning will occur if the controller detects a short circuit in the probe for
10 seconds. The probe will need to be replaced. To order a new probe, go to
traegergrills.com.
ERROR CLEARING
Errors are cleared with the Menu - Settings - Clear Notications menu item. Since each error will send the grill into a
cooldown, if an error is cleared while the grill is cooling down, the main screen will display “Cooling Down . . .” until the
cooldown is complete. Note that some errors, like Temp Sensor Out, will trigger again even afer clearing them. This is a
sign that the conditions that caused the error have not changed. Power-cycling the grill will also clear any errors, as many
users are accustomed to.
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Traeger Pro 575 - 780 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Traeger Pro 575 - 780

Traeger Pro 575 - 780 Bedienungsanleitung - Deutsch - 32 seiten

Traeger Pro 575 - 780 Bedienungsanleitung - Holländisch - 32 seiten

Traeger Pro 575 - 780 Bedienungsanleitung - Französisch - 32 seiten

Traeger Pro 575 - 780 Bedienungsanleitung - Spanisch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info