688812
15
Zoom out
Zoom in
Vorherige Seite
1/23
Nächste Seite
EN 15
local air conditioner PAC 2010 E / PAC 2610 E
Key lock (remote control only)
The function can be activated via the remote control both during
operation and in standby mode.
The key lock applies to the remote control only – the control
panel at the device is not affected and can be used nonetheless.
1. Simultaneously press the plus/ minus buttons(27, 32) on
the remote control.
ð The key lock is activated. The remote control cannot
send signals to the device.
ð The LOCK indication can be seen on the remote
control's display(25).
2. Simultaneously press the plus/ minus buttons(27, 32)
once more.
ð The key lock is deactivated.
ð The LOCK indication on the remote control's display(25)
disappears.
Switching the control panel illumination on and off
The illumination of the control panel can be switched on or off
via the remote control both during operation and in standby
mode.
1. Simultaneously press the plus button(27) and the
FAN button(31) on the remote control for 3s.
ð The control panel illumination will be switched off.
ð The device continues to run with the selected settings.
2. Simultaneously press the plus button(27) and the
FAN button(31) again for 3s.
ð The control panel illumination will be switched back on.
Self-cleaning function / Internal drying
This function serves to dry the interior of the device in order to
prevent the formation of mould or similar inside the device due
to residual moisture.
The self-cleaning function should be used if the device is not
operated or is stored for a longer period of time.
This function can be activated via the remote control during
cooling and dehumidification.
The fan continues to run at low speed for a while after the
device has been switched off.
Please proceed as follows to activate the self-cleaning function/
internal drying:
1. Select the operating mode cooling or dehumidification.
2. Press the X-FAN button(28) on the remote control.
ð The X-FAN indication can be seen on the remote
control's display(25).
3. Press the ON/OFF button(33) to switch the device off.
ð The fan continues to run at low speed for a while. Then
the fan switches off as well.
4. You can deactivate the self-cleaning function/ internal
drying at any time by pressing the X-FAN button(28)
again.
Memory function
After a power failure during operation the device will
automatically be switched back on. The chosen operating mode
settings will be saved, a possibly programmed timer will not.
All the chosen settings (incl. timer) remain saved on the remote
control. As soon as the device receives an input from the remote
control, the settings will be transmitted from the remote control
to the device.
The compressor may start up with a delay of 3min, as it is
provided with an internal protection against direct restart.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator.
The device will then carry out an automatic defrost.
The compressor switches off and the fan keeps running until
defrosting is completed. The duration of the defrost process can
vary.
Do not switch the device off during automatic defrost. Do not
remove the mains plug from the mains socket.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Empty the condensation tray if necessary.
If necessary, remove the condensation drain hose and any
residual fluid from it.
If necessary, carry out self-cleaning (see chapter
Self-cleaning function).
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trotec PAC2010E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Trotec PAC2010E

Trotec PAC2010E Bedienungsanleitung - Deutsch - 23 seiten

Trotec PAC2010E Bedienungsanleitung - Holländisch - 23 seiten

Trotec PAC2010E Bedienungsanleitung - Französisch - 23 seiten

Trotec PAC2010E Bedienungsanleitung - Spanisch - 23 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info