631208
11
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
Cut off the ventilation hose approx. 20 mm below the floor of
the vehicle at an angle of 45° to the direction of travel.
45º
20 mm
21
13
12
20
Ø 12 mm
Produce connection (22) for cold water supply between
safety/drain valve (14) and elbow (13 – lower pipe) on water
heater.
Route the hot water pipe (23) from the elbow with integrated
breather valve (12 – upper pipe) to the hot water consumers.
Gas connection
38
The operating pressure for the gas supply is 30 mbar
and must correspond to the operating pressure of the
appliance (see name plate).
The 8 mm gas supply line is connected to the connection noz-
zle (38) with cutting ring connection. The cutting rings are to
be selected according to the gas pipe used (for copper pipe:
support sleeves and brass cutting ring as supplied). Carefully
hold in place with a second wrench when tightening!
Before connecting to the water heater make sure that the gas
lines are free from dirt, chips and such!
Route the pipes in such a way that the appliance can be
removed again for servicing.
In areas frequented by people, keep the number of parting
connections in the gas supply line to an technically feasible
minimum.
The entire system must accord with the technical and
administrative provisions of the individual country of use
(e.g. EN 1949 for vehicles). National specifications and
regulations must be respected.
Flexible water hose routing
As special accessories Truma supplies the water connectors
(12 + 13) and safety/drain (14) valve with a 10 mm diameter
hose nipple (please refer to page 14).
Pressure-resistant (up to 4.5 bar) and hot water-resistant water
hoses in food quality with an internal diameter of 10 mm must
be used.
Route water hoses so that they are as short and free
of kinks as possible. All hose connections must be
secured using hose clamps (also for cold water)! Pressures
of up to 4.5 bar can occur in the safety/drain valve (also with
submergible pumps) because of the heat of the water and the
resulting expansion.
All hot water hoses should be routed in a descending
manner to the safety/drain valve! Otherwise no guaran-
tee of protection from frost!
Installation of the safety (pressure relief)
drain valve
Ø 18 mm
14
15
Install the safety/drain valve
(14) at a place which is
easily accessible, near the
water heater. Drill hole with
18 mm diameter and pass
through discharge socket
with hose (15). Fasten safety/
drain valve with 2 screws.
The draining is to be directly
to the outside at a position
protected against splash
water (apply splash guard, if
necessary).
Water pipe routing
Connect cold water supply (16) to safety/drain valve (14).
Direction of flow is unimportant.
14
16
13
12
22
20
23
Slide elbow fitting (13) onto cold water connecting pipe (lower
pipe) and elbow fitting with integrated ventilating valve (12)
onto hot water connecting pipe (upper pipe) of water heater
as far as it will go. Pull in opposite direction in order to make
sure the elbow fittings are securely attached.
Push the venting hose, external diameter 11 mm (20), onto
the hose grommet of the venting valve (21), and lay it to the
outside without any kinks. Ensure that the bend radius is not
smaller than 40 mm.
11
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Truma Ultrastore Rapid GE wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info