544145
17
Zoom out
Zoom in
Vorherige Seite
1/88
Nächste Seite
17
Always observe the opera ting instructions and “Impor-
tant operating notes“ prior to starting! The vehicle owner
is responsible for the correct operation of the appliance!
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the ap-
pliance, to a place in the vehicle where it is clearly visible to
all users (e.g. on the wardrobe door)! Ask Truma to send you
stickers, if necessary.
Control panel with slide switch
ab
a = Slide switch
Heating – Off – Ventilation
b = Slide switch
High setting (large flame symbol)
Low setting (small flame symbol)
Control panel with rotary switch
Trumatic E
1
3
5
7
9
d
c
e
c = “Heating“ rotary switch
High setting (large flame symbol)
Low setting (small flame symbol)
d = “Off“ rotary switch
e = “Ventilation“ rotary switch
High setting (large symbol)
Low setting (small symbol)
Switching on the Heating
Remove cowl cap.
Turn on gas cylinder and open quick-acting valve in the gas
supply line.
Adjust desired room temperature at rotary knob.
Switching the heating on:
Control panel with slide switch
Set the switch (a) to Heating and switch (b) to the desired
output setting.
Control panel with rotary switch
Set the rotary switch to the desired output setting (c).
If the outside temperature is low, switch to high setting.
The Trumatic E heater has been tested and approved for
operation, also when the vehicle is moving. The burner
with fan assistance guarantees satisfactory operation, even
under extremely windy conditions. It may be necessary to ob-
serve respective, country-specific regulations for the operation
of liquid gas appliances when the vehicle is moving.
Operating instructions
Switching on the Ventilation
Control panel with slide switch
Set switch (a) to Ventilation and switch (b) to the desired
output setting.
Control panel with rotary switch
Set the rotary switch to the desired output setting (e).
Switching off
Set the slide switch (a) or the rotary switch (d) to the centre.
If the appliance is switched off after a heating phase, the fan
can continue running in order to make use of the residual heat.
If the appliance is not used for a prolonged period of time,
mount the cowl cap, close quick-acting valve in the gas sup-
ply line and turn off gas cylinder.
Green LED “Operating”
(under rotary control knob)
When the device is switched on (heating or ventilation), the
green LED must light up (the fan is operational). If the LED
does not shine, check the (main) switch. For this purpose ob-
serve respective instructions of the vehicle manufacturer.
During the heating process whilst the flame is burning, the
green LED shines twice as brightly. This also makes it possible
to determine the instantaneous switching point of the room
temperature.
Fuses
The device and control panel fuses are on the electronic con-
trol unit on the device.
Device fuse (F1):
3.15 AT – slow – (EN 60127-2-3)
Control panel fuse (F3):
1.6 AT – slow –
The fine-wire fuse must only be replaced by a fuse of the
same design.
Red LED “Failure”
In the event of a failure, the red LED shines. Possible causes
for the failure can be e.g. no gas, insufficient combustion air,
heavily soiled rotor, defective fuse etc.. Deactivate by switch-
ing off and then switching on again.
Opening a window to which a window switch is attached
and closing it again is the equivalent of switching the equip-
ment off and on again at the control panel (e.g. a fault reset)!
Flash operation indicates that the operating voltage is too
low or too high for the appliance (charge battery, if necessary).
In Germany, always notify the Truma Service Centre if prob-
lems are encountered; in other countries the relevant service
partners should be contacted (see Truma Service Booklet or
www.truma.com).
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Trumatic E 4000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info