815508
38
Zoom out
Zoom in
Vorherige Seite
1/54
Nächste Seite
3838 3-90-30007467Vermont Castings • Stardance SDDVT Installation Manual_R35 • 11/23
M.Troubleshooting-(Continued)
Symptom PossibleCause Corrective Action
Pilot sparks but does not light, after 90
sec, 3 Red/1 Green Lockout
No gas supply.
Verify incoming gas line ball valve is ‘Open’. Verify inlet
pressure is within requirement for gas type used. Contact
gas supplier.
ECM has poor ground. Verify wiring, check valve harness black wire is securely
grounded to metal chassis.
Gas valve defective.
Check pilot valve solenoid kick and hold voltages during
ignition cycle. Kick V should be >1 V, hold V minimum
0.26 V. If voltages are OK, replace gas valve.
Pilot lights but main burner does not
light. Pilot continues to spark for 90 sec
then goes into 3 Red/1 Green Lockout.
No ame detected. Flame
rectication issue.
Check if white sense lead is securely connected to
‘S’ terminal of IFT-ECM. Check resistance of sense
lead between sense rod tip and connector to IFT-ECM,
should be less than 1 ohm - if not, replace pilot assembly.
Check system ground, ensure black valve harness wire
is securely attached to metal chassis. Check wiring for
damage. With system OFF, check resistance between
tip of sense rod and pilot hood, should be resistance (>1
M-ohm).
No ame detected or sense
rod contamination.
With glass assembly installed, verify pilot ame is
engulng ame sense rod on pilot assembly. Verify inlet
gas pressure is correct for gas type. Polish ame sense
rod with ne steel wool to remove any contaminants that
may have accumulated.
Pilot lights and recties, but main burner
does not light. Main valve solenoid.
Check if green wire in valve harness is connected to
green main valve solenoid. Check main valve solenoid
resistance, nominal is 60 ohms. If open or shorted, replace
valve. Verify valve inlet pressure is correct for gas type.
Pilot and main do not light, ECM goes
into 5 Red/1 Green Lockout. Power Vent (PV) Failure.
Power Vent blower defective - check wiring to IFT-ACM,
check if blower is working. Check if PV pressure switch
is connected to brown and black wire in 6-pin valve wire
harness. Check if pressure switch is closed (shorted)
when PV blower is running. Refer to PV troubleshooting
instructions.
Appliance lights and runs for a few
minutes then shuts down and/or
appliance cycle ON and OFF with less
than 90 sec of ON time.
Shorted or loose connection
in ame detection circuit.
Check if white sense lead is securely connected to
‘S’ terminal of IFT-ECM. Check resistance of sense
lead between sense rod tip and connector to IFT-ECM,
should be less than 1 ohm - if not, replace pilot assembly.
Check system ground, ensure black valve harness wire
is securely attached to metal chassis. Check wiring for
damage. With system OFF, check resistance between
tip of sense rod and pilot hood, should be resistance (>1
M-ohm).
Poor ame rectication or
contaminated sense rod.
With glass assembly installed, verify pilot ame is
engulng ame sense rod on pilot assembly. Verify inlet
gas pressure is correct for gas type. Polish ame sense
rod with ne steel wool to remove any contaminants that
may have accumulated. Verify no soot deposits are in
sense rod to pilot hood gap.
Logs are set up wrong. Remove and re-install logs per the log placement
instructions.
Damaged pilot assembly.
Verify the pilot assembly ceramic insulator around the
ame sensing rod is not cracked, damaged or loose.
Check resistance between tip of sense rod and IFT-ECM
connector, should be less than 1 ohm. Replace pilot
assembly if damage is detected.
38

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vermont Castings Stardance Series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Vermont Castings Stardance Series

Vermont Castings Stardance Series Bedienungsanleitung - Französisch - 54 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info