4) Tip the machine on its back and remove the two, small Phillips head screws on the bottom of the machine along
the back edge of the bottom. Stand the machine back on its feet
5) Remove the 6 screws on the outer case (three on each side). Slide the outer case off the machine
6) Replace the water reservoirs platform and the reservoir and replace the hoses back into the reservoir.
7) Pour the de-scaling agent into the water reservoir. You will need to fill it at least 1/2 full. Be sure to follow the
manufacturers recommendations as to the mixing of the de-scaler to the proper concentration.
8) Plug the machine in and turn the power switch to Position I only! Allow the boiler to fill. Continue to the next
step after the pump stops.
WARNING: In many of the following steps, such as when pumping the de-scaler through the group-
head and removing the hoses from the water tank, splashing acid can create a safety hazard. Gloves, eye
protection, and protection for the working surface are required.
9) Place a suitable container under the grouphead and turn on the brew function to run about eight ounces out of
the machine to get the de-scaling agent through the grouphead. This also ensures that the thermosyphon pipes,
the inside of the heat exchanger and internal portions of the grouphead get de-scaled.
CAUTION: If the used de-scaling agent is poured down a drain, allow the faucet to run into the sink
to dilute the acid. Never re-use the spent acid.
10) Snap the blind filter into the portafilter handle and backflush the machine. Turn on the brew function and
allow it to run for about five seconds. This will force the de-scaler through the over pressure relief valve. You
will see the liquid flowing back into the reservoir through the secondary hose. When that takes place, turn the
machine to “0” and unplug the power cord. Leave the hoses in place and move the reservoir off to the side of
the machine and lift off the reservoir platform.
11) Remove the two Phillips head screws holding the top of the divider panel and swing it back and off the ma-
chine. Take care not to stress the wires attached to the water-level microswitch which is attached to the panel.
12) Remove the water level sensor wire by loosening the screw indicated in these two photos. Leave it discon-
nected for now. This will fool the boiler into thinking that the boiler is low on water and needs to be refilled.
Set the wire off to the side where it cannot accidently
connect with any metal parts.
13) Replace the divider panel and reinstall the two Phil-
lips head screws holding the top of the divider panel
in place. Reinstall the reservoir platform and reservoir
and insert the hoses once again. If needed, refill the res-
ervoir with de-scaling agent.
14) With the autofill wire still disconnected, plug the
machine back in, remove the tip and O-ring from the
steam wand and place them off to the side. Place a suit-
able container under the steam wand and the hot water
wand and open the steam valve.
15) Turn the power switch to position “I” only. The au-
tofill is defeated and so the machine will overfill (com-
pletely fill) the boiler. As soon as a solid stream comes
out of the steam wand, turn the power switch to Position
0 and close the steam valve.
35

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vibiemme Domobar Super wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info