28 While waiting for the descaler to work, remove the reservoir and empty it. Take care not to allow the
reservoir hose to drip or splash descaler. Rinse the reservoir out with clean water, and dry it. Replace the
reservoir and fill to within approximately 1/2 inch (2 cm) of the top with clean water. Replace the pickup
hose into the reservoir.
29 After the required wait time (Step 27), turn the power switch to “Position 0.
30 Place the vessel under the hot water wand and open the valve. Turn the valve off when no more liquid
comes from the wand. If the vessel becomes full, close the valve, empty it and repeat until no more liquid
comes from the wand.
31 Empty the drip tray if necessary.
32 Turn the power switch to “Position I.” The pump will start and fill the boiler again.
33 When the pump stops, turn the power switch to “Position II.The PID display should still read “oFF.Al-
low the pressure in the steam boiler to rise.
34 When pressure has reached the normal operating pressure, turn the power switch to “Position 0.
35 Place your vessel under the hot water wand and open the valve. Turn the valve off when no more liquid
comes from the wand. If the vessel becomes full, close the valve, empty it and repeat until no more liquid
comes from the wand.
36 FOR PLUMBED MACHINES ONLY -
At this time you can switch back to your plumbed option to make the rest of these steps easier. Remove
the reservoir and replace the screw in the center of the reservoir’s platform. Tighten it until you hear the
“click” of the water-level microswitch, and then at least one more additional turn. Failure to tighten the
screw will keep the machine from operating. You MUST also switch the water source selector lever on
the bottom of the machine back to the plumbed option. The lever should be pointing towards the steam
wand, which is to your left while facing the front of the machine. Rinse, dry and replace the reservoir,
and place the hose back into the reservoir.
CAUTION: Failure to switch the machine back to the plumbed option after tightening the
screw in the center of the reservoir platform will allow the pump to run without a water sup-
ply. This has the potential to damage the pump in a short time. Pump damage caused by run-
ning it dry is not covered by the warranty.
37 Refill the reservoir with clean water if using the reservoir option as the selected water source.
38 Turn the power switch to “Position I.The steam boiler should go through a refill cycle and stop. When
the pump stops, turn the power switch to “Position II.” Allow the steam boiler to come back up to normal
operating pressure as indicated on the steam boiler’s gauge.
39 Place the vessel under the hot water wand, open the valve and dispense about 6 ounces of water, then
close the valve and discard the dispensed liquid. When the pump stops and the boiler comes back up to pres-
sure, once again dispense about 6 ounces of water through the hot water tap. Rinse and dry the vessel and
dispense another 6 ounces into the vessel. Allow that water to cool sufficiently, and if it smells clean and
free of descaling solution, use a clean, dry spoon and sample one or two drops of the water just as you did
for the brew water. If any of the acid taste remains, repeat the six-ounce flush and tasting process until the
water is free of acidic taste.
CAUTION: Most proper de-scaling agents are a form of acid which is food safe, and in highly di-
luted form is relatively safe to consume. Read the label of the product you are using to be sure it is
safe before sampling the discarded water. Sample only a very small amount.
40 When the water from the hot water wand is clean and free from the acidic taste of the cleaner, place a
steaming pitcher under the steam wand and slowly and carefully open the steam wand and dispense steam
for at least fifteen seconds. Close the valve, rinse the pitcher with clean, cool, water. When the steam pres-
sure builds, repeat the steam flush into the empty steaming pitcher. After closing the steam valve, carefully
66

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Vibiemme Vibiemme Double Domobar version 3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Vibiemme Vibiemme Double Domobar version 3

Vibiemme Vibiemme Double Domobar version 3 Zusatzinformation - Englisch - 3 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info