8. Installation
This product contains potentially dangerous voltages. It should only be installed under the supervision of a suitable
qualified installer with the appropriate training, and subject to local requirements. Please contact Victron Energy for
further information or necessary training
8.1 Location
The product must be installed in a dry and well-ventilated area, as close as possible to the batteries. There should be a
clear space of at least 10 cm around the product for cooling.
WARNING: Excessively high ambient temperature will result in the following:
Reduced service life.
Reduced charging current.
Reduced peak capacity, or shutdown of the inverter. Never position the appliance directly above the batteries.
This product is suitable for wall mounting. For mounting purposes, a hook and two holes are provided at the back of the
casing (see appendix G). The device can be fitted either horizontally or vertically. For optimal cooling, vertical fitting is
preferred.
WARNING: The interior of the product must remain accessible after installation.
Try and keep the distance between the product and the battery to a minimum in order to minimize cable voltage losses.
For safety purposes, this product should be installed in a heat-resistant environment. You should prevent the presence of
e.g. chemicals, synthetic components, curtains or other textiles, etc., in the immediate vicinity.
8.2 Connection of battery cables
In order to utilize the full capacity of the product, batteries with sufficient capacity and battery cables with sufficient cross
section should be used. See table.
48/3000/35
Recommended battery capacity (Ah)
100–400
Recommended DC fuse
125 A
Recommended cross section (mm²) per + and - connection terminal
0 5 m
35 mm²
5 10 m
70 mm²
Remark: Internal resistance is the important factor when working with low capacity batteries. Please consult your supplier
or the relevant sections of our book 'Energy Unlimited', downloadable from our website.
8.3 Battery Connection Procedure
Proceed as follows to connect the battery cables:
WARNING: Use a torque wrench with insulated box spanner in order to avoid shorting the battery.
Maximum torque: 14 Nm Avoid shorting the battery cables.
WARNING: Specific care and attention must be taken when making the battery connections. Correct polarity must be
confirmed with a multimeter before connection. Connecting a battery with incorrect polarity will destroy the device and is
not covered by warranty.
Undo the two screws at the bottom of the enclosure and remove the service panel.
Connect the battery cables. First the - cable then the +. Be aware that there may be a spark when making the
battery connections.
Tighten the nuts to the prescribed torques for minimal contact resistance.
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info